Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 232

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

New and Improved Methods to Characterize Glycemic Variability Using Continuous Glucose Monitoring

Rodbard, David·2009·Diabetes Technology & Therapeutics

Abstract

BACKGROUND: Glycemic variability is a possible risk factor for development of complications from diabetes. Numerous methods have been used to characterize glycemic variability. METHODS: We propose several new methods to characterize glycemic variability. We evaluated these methods empirically and theoretically and compared them with previous methods. RESULTS: We describe (1) extension and generalization of the mean amplitude of glycemic excursion (MAGE), i.e., "within day variability," (2) extension and generalization of the mean of daily differences (MODD), i.e., the "between day-within time points variability," (3) "between daily means variability," (4) "between time points variability" of the glucose profile averaged over several days, (5) "within series variability" for a time segment of any arbitrary length, (6) new measures of the stability of the daily glycemic patterns, (7) new types of graphical displays, including within day variability, between day-within time points variability, and between daily means variability versus total variability, and between daily means variability versus within day variability, and (8) new methods to evaluate whether within series and between day-within time points variability fluctuate systematically by time of day. We examined the new measures in relation to previous measures of glycemic variability using correlation analysis on a clinical dataset for 85 subjects. MAGE, MODD, and continuous overall net glycemic action (CONGA(n)) are directly proportional to total standard deviation (SD). MAGE is highly correlated with both total SD and within day variability but weakly correlated with measures of between day variability. MODD is highly correlated with between day-within time points variability and total SD but weakly correlated with measures of within day variability. CONCLUSIONS: We provide a systematic, logical framework to characterize multiple aspects of glycemic variability and have implemented a simple, practical computing format. This approach can help clinical researchers and clinicians identify the major sources of variability for any given patient and monitor responses to interventions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2009.0015

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 232

Metadata

Authors
Rodbard, D.
Venue
Diabetes Technology & Therapeutics
Published
2009-09
Volume
11
Issue
9
Pages
551-565
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2046393196
Cited by
232
References
2
FWCI
8.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New and Improved Methods to Characterize Glycemic Variability Using Continuous Glucose Monitoring. https://app.cochat.ai/papers/10.1089/dia.2009.0015
The paper
Rodbard, D. (2009). New and Improved Methods to Characterize Glycemic Variability Using Continuous Glucose Monitoring. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2009.0015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.