CoChat

The Performance of a Glucose-Ketone Meter in the Diagnosis of Diabetic Ketoacidosis in Patients with Type 2 Diabetes in the Emergency Room

Voulgari, Christina, Tentolouris, Nicholas · 2010 · Diabetes Technology & Therapeutics
Cited by 40

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Diabetic ketoacidosis (DKA) is a serious metabolic complication. One of its precipitating causes is insulin omission. DKA requires early diagnosis and strict glucose control, which increases the use of glucose meters in the Emergency Room (ER). We aimed to determine the performance of a glucose-ketone meter in the diagnosis of DKA. METHODS: From 450 type 2 diabetes mellitus insulin-treated patients attending the ER with a capillary glucose level >13.9 mmol/L, 50 patients (26 men and 24 women, mean age 60.2 +/- 8.2 years) had DKA. Capillary glucose and beta-hydroxybutyrate (beta-OHB) were measured with the Precision-Xtra device (Abbott Laboratories, Abingdon, UK). Serum glucose and biochemical parameters were measured on an automatic analyzer; serum beta-OHB was determined using an enzymatic end-point spectrophotometric method. Urine ketones were determined using a semiquantitative assay (Ketodiastix, Bayer Diagnostics, Stoke Poges, Slough, UK). RESULTS: Serum and capillary beta-OHB values were highly correlated (r = 0.99, P < 0.001), and the mean difference between them was 0.49 mmol/L (95% confidence interval [CI], 0.35-0.95 mmol/L; P = 0.81). Similarly, serum and capillary glucose values were significantly correlated (r = 0.86, P < 0.001), and the mean difference between them was 0.43 mmol/L (95% CI, 0.82-0.93 mmol/L; P = 0.71). Patients with DKA were inadequately treated with insulin and missed clinic appointments: 80% of patients with DKA compared to 20% of patients without DKA. In all cases, DKA was attributed to insulin omission. Capillary ketonemia (beta-OHB >3.0 mmol/L) had the highest performance (sensitivity 99.87%, specificity 92.89%, positive predictive value 92.89%) for the diagnosis of DKA compared with serum ketonemia (sensitivity 90.45%, specificity 88.65%, positive predictive value 87.76%) or ketonuria (sensitivity 89.89%, specificity 52.73%, positive predictive value 41.87%). CONCLUSIONS: Implementation of measures such as home glucose and ketone monitoring can possibly decrease the number of hospital admissions due to DKA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2010.0011

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 40

Metadata

Authors
Voulgari, C., & Tentolouris, N.
Venue
Diabetes Technology & Therapeutics
Published
2010-07
Volume
12
Issue
7
Pages
529-535
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2135630468
Cited by
40
References
5
FWCI
2.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Performance of a Glucose-Ketone Meter in the Diagnosis of Diabetic Ketoacidosis in Patients with Type 2 Diabetes in the Emergency Room. https://app.cochat.ai/papers/10.1089/dia.2010.0011
The paper
Voulgari, C., & Tentolouris, N. (2010). The Performance of a Glucose-Ketone Meter in the Diagnosis of Diabetic Ketoacidosis in Patients with Type 2 Diabetes in the Emergency Room. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2010.0011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.