CoChat

Sustained Efficacy of Continuous Subcutaneous Insulin Infusion in Type 1 Diabetes Subjects with Recurrent Non-Severe and Severe Hypoglycemia and Hypoglycemia Unawareness: A Pilot Study

Giménez, Marga, Lara, Mercè, Conget, Ignacio · 2010 · Diabetes Technology & Therapeutics
Cited by 38

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

BACKGROUND: This study evaluated the effect of CSII on hypoglycemia awareness and on glucose profile in type 1 diabetes (T1D) subjects with repeated non-severe or severe hypoglycemia (NS or SH, respectively). METHODS: We included subjects (1) older than 18 years, (2) with T1D duration of >5 years, (3) on multiple doses of insulin, and (4) without micro- or macrovascular complications and more than four NS events per week (in the last 8 weeks) and more than two SH events (in the last 2 years). NS/SH episodes and hypoglycemia awareness were evaluated. A 72-h continuous glucose monitoring (CGM) was performed before continuous subcutaneous insulin infusion (CSII). A hypoglycemia-induced test was used to evaluate each patient's symptoms in euglycemia/hypoglycemia. Quality of life (QoL) was also evaluated. After 6, 12, and 24 months, all the subjects were reevaluated. RESULTS: Twenty subjects were included (34.0 +/- 7.5 years old, 12 women, A1c 6.7 +/- 1.1%, 16.2 +/- 6.6 years of diabetes' duration). At baseline, 19 out of 20 subjects displayed hypoglycemia unawareness, which diminished significantly during the follow-up (3 out of 20). NH episodes per week diminished from 5.40 +/- 2.09 at baseline to 2.75 +/- 1.74 at the end of the follow-up (P < 0.001). SH episodes fell from 1.25 +/- 0.44 per subject-year to 0.05 +/- 0.22 after 24 months (P < 0.001). Hemoglobin A1c remained unaltered. With CGM, the percentage of values within 70-180 mg/dL increased (53.2 +/- 11.0% to 60.3 +/- 17.1%, P = 0.13), and the percentage of values <70 mg/dL decreased (13.7 +/- 9.4% to 9.1 +/- 5.2%, P = 0.07), after 24 months. Mean amplitude of glycemic excursions diminished after 24 months of CSII (136 +/- 28 mg/dL to 115 +/- 19 mg/dL; P < 0.02). An improvement in all the aspects of QoL was observed. The basal alteration in symptom response to an induced hypoglycemia improved after 24 months of initiating CSII leading to a response indistiguishable from that observed in a control group of subjects with T1D without repeated NH and SH. CONCLUSIONS: CSII prevents hypoglycemic episodes, improves hypoglycemia awareness, and ameliorates glycemic profile in T1D subjects with repeated NS/SH. Its use is also associated with an improvement in diabetes QoL.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2010.0028

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 38

Metadata

Authors
Giménez, M., Lara, M., & Conget, I.
Venue
Diabetes Technology & Therapeutics
Published
2010-07
Volume
12
Issue
7
Pages
517-521
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1964657944
Cited by
38
References
12
FWCI
3.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.