CoChat

Calculating the Mean Amplitude of Glycemic Excursion from Continuous Glucose Monitoring Data: An Automated Algorithm

Baghurst, Peter A. · 2011 · Diabetes Technology & Therapeutics
Cited by 110

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Glycemic variability is currently under scrutiny as a possible predictor of the complications of diabetes. The manual process for estimating a now classical measure of glycemic variability, the mean amplitude of glycemic excursion (MAGE), is both tedious and prone to error, and there is a special need for an automated method to calculate the MAGE from continuous glucose monitoring (CGM) data. METHODS: An automated algorithm for identifying the peaks and nadirs corresponding to the glycemic excursions required for the MAGE calculation has been developed. The algorithm takes a column of timed glucose measurements and generates a plot joining the peaks and nadirs required for estimating the MAGE. It returns estimates of the MAGE for both upward and downward excursions, together with several other indices of glycemic variability. RESULTS: Details of the application of the algorithm to CGM data collected over a 48-h period are provided, together with graphical illustrations of the intermediate stages in identifying the peaks and nadirs required for the MAGE. Application of the algorithm to 104 CGM datasets (92 from children with diabetes and 12 from controls) generated plots that, on visual inspection, were all found to have identified the peaks, nadirs, and excursions correctly. CONCLUSIONS: The proposed algorithm eliminates the tedium and/or errors of manually identifying and measuring countable excursions in CGM data in order to estimate the MAGE. It can also be used to calculate the MAGE from "sparse" blood glucose measurements, such as those collected in home blood glucose monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2010.0090

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 110

Metadata

Authors
Baghurst, P. A.
Venue
Diabetes Technology & Therapeutics
Published
2011-03
Volume
13
Issue
3
Pages
296-302
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1978533569
Cited by
110
References
2
FWCI
5.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Calculating the Mean Amplitude of Glycemic Excursion from Continuous Glucose Monitoring Data: An Automated Algorithm. https://app.cochat.ai/papers/10.1089/dia.2010.0090
The paper
Baghurst, P. A. (2011). Calculating the Mean Amplitude of Glycemic Excursion from Continuous Glucose Monitoring Data: An Automated Algorithm. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2010.0090

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.