Fear of Hypoglycemia in Type 1 Diabetes Managed by Continuous Subcutaneous Insulin Infusion: Is It Associated with Poor Glycemic Control?
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: We surveyed the extent of fear of hypoglycemia in people with type 1 diabetes treated by continuous subcutaneous insulin infusion (CSII) and tested the hypothesis that suboptimal glycemic control during CSII is related to fear of hypoglycemia. METHODS: We audited nonpregnant type 1 diabetes patients attending an Insulin Pump Clinic with at least 6 months' duration of CSII. In 104 eligible subjects, fear of hypoglycemia was assessed by questionnaire; 75 responded. RESULTS: The median duration of CSII was 5 years (range, 1-29 years). Poor glycemic control (hemoglobin A1c [HbA1c] ≥ 8.5%; mean ± SD, 9.1 ± 1.0%) was present in 27%, and this group had more men than a good-control group with HbA1c < 7.0% (43% vs. 11%). Substantial fear of hypoglycemia (score > 50%) occurred in 27% of subjects, but fear of hypoglycemia was not correlated with HbA1c. The only significant correlates of fear of hypoglycemia were accumulated episodes of severe hypoglycemia (r = 0.48, P < 0.001) and rate of hypoglycemia on CSII (r = 0.48, P < 0.001). The HbA1c on CSII was correlated with multiple daily injection (MDI) HbA1c (r = 0.66, P < 0.001) and the change in HbA1c (r = 0.63, P < 0.001). CONCLUSIONS: Fear of hypoglycemia is not correlated with, and is unlikely to be a major determinant of, HbA1c on CSII. Other factors (such as HbA1c on MDI and adherence to insulin pump procedures) are likely to be more important. Nevertheless, substantial fear of hypoglycemia is present in many CSII-treated people and may adversely affect quality of life and psychological well-being.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fear of hypoglycemia: quantification, validation, and utilization
Cox, D. J., Irvine, A., Gonder-Frederick, L., Nowacek, G., & Butterfield, J. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.617 · Cited by 579
Wild, D., von Maltzahn, R., Brohan, E., Christensen, T., Clauson, P., & Gonder-Frederick, L. (2007) · Patient Education and Counseling · doi:10.1016/j.pec.2007.05.003 · Cited by 545
Recall of severe hypoglycaemia and self‐estimated state of awareness in type 1 diabetes
Pedersen‐Bjergaard, U., Pramming, S., & Thorsteinsson, B. (2003) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.377 · Cited by 240
Olinder, A. L., Kernell, A., & Smide, B. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00462.x · Cited by 129 · cited 1×
“In considering what factors may influence glycemic control on CSII, apart from HbA1c on MDI, it is of note that others have found that a reduced number of bolus administrations 21–23 and a reduced frequency of blood glucose self-monitoring 10,24 are both associated with poorer control on CSII.”
Cited by
Insulin-pump therapy for type 1 diabetes mellitus
Pickup, J. C. (2012) · New England Journal of Medicine · doi:10.1056/nejmct1113948 · Cited by 270
Self-citationUnderstanding the construct of fear of hypoglycemia in pediatric type 1 diabetes
Shepard, J. A., Vajda, K., Nyer, M., Clarke, W., & Gonder-Frederick, L. (2014) · Journal of Pediatric Psychology · doi:10.1093/jpepsy/jsu068 · Cited by 82
Heller, S., White, D., Lee, E., Lawton, J., Pollard, D., Waugh, N., Amiel, S., Barnard, K., Beckwith, A., Brennan, A., et al. (2017) · Health Technology Assessment · doi:10.3310/hta21200 · Cited by 73
Hajós, T. R. S., Polonsky, W. H., Pouwer, F., Gonder-Frederick, L., & Snoek, F. J. (2014) · Diabetes Care · doi:10.2337/dc13-0971 · Cited by 58
Chatwin, H., Broadley, M., Speight, J., Cantrell, A., Sutton, A., Heller, S., de Galan, B., Hendrieckx, C., & Pouwer, F. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108752 · Cited by 53
Metadata
- Authors
- Nixon, R., & Pickup, J. C.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2011-02
- Volume
- 13
- Issue
- 2
- Pages
- 93-98
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2085017501
- Cited by
- 51
- References
- 4
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fear of Hypoglycemia in Type 1 Diabetes Managed by Continuous Subcutaneous Insulin Infusion: Is It Associated with Poor Glycemic Control? https://app.cochat.ai/papers/10.1089/dia.2010.0192
- The paper
- Nixon, R., & Pickup, J. C. (2011). Fear of Hypoglycemia in Type 1 Diabetes Managed by Continuous Subcutaneous Insulin Infusion: Is It Associated with Poor Glycemic Control? Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2010.0192
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.