CoChat

Can a Tool That Automates Insulin Titration Be a Key to Diabetes Management?

Open access
Bergenstal, Richard M., Bashan, Eran, McShane, Margaret, Johnson, Mary, Hodish, Israel · 2012 · Diabetes Technology & Therapeutics
Cited by 38

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Most patients who use insulin do not achieve optimal glycemic control and become susceptible to complications. Numerous clinical trials have shown that frequent insulin dosage titration is imperative to achieve glycemic control. Unfortunately, implementation of such a paradigm is often impractical. We hypothesized that the Diabetes Insulin Guidance System (DIGS™) (Hygieia, Inc., Ann Arbor, MI) software, which automatically advises patients on adjustment of insulin dosage, would provide safe and effective weekly insulin dosage adjustments. SUBJECTS AND METHODS: In a feasibility study we enrolled patients with type 1 and type 2 diabetes, treated with a variety of insulin regimens and having suboptimal glycemic control. The 12-week intervention period followed a 4-week baseline run-in period. During the intervention, DIGS processed patients' glucose readings and provided insulin dosage adjustments on a weekly basis. If approved by the study team, the adjusted insulin dosage was communicated to the patients. Insulin formulations were not changed during the study. The primary outcome was the fraction of DIGS dosage adjustments approved by the study team, and the secondary outcome was improved glycemic control. RESULTS: Forty-six patients were recruited, and eight withdrew. The DIGS software recommended 1,734 insulin dosage adjustments, of which 1,731 (99.83%) were approved. During the run-in period the weekly average glucose was stable at 174.2±36.7 mg/dL (9.7±2.0 mmol/L). During the following 12 weeks, DIGS dosage adjustments resulted in progressive improvement in average glucose to 163.3±35.1 mg/dL (9.1±1.9 mmol/L) (P<0.03). Mean glycosylated hemoglobin decreased from 8.4±0.8% to 7.9±0.9% (P<0.05). Concomitantly, the frequency of hypoglycemia decreased by 25.2%. CONCLUSIONS: The DIGS software provided patients with safe and effective weekly insulin dosage adjustments. Widespread implementation of DIGS may improve the outcome and reduce the cost of implementing effective insulin therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2011.0303

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 38

Metadata

Authors
Bergenstal, R. M., Bashan, E., McShane, M., Johnson, M., & Hodish, I.
Venue
Diabetes Technology & Therapeutics
Published
2012-08
Volume
14
Issue
8
Pages
675-682
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2091252422
Cited by
38
References
9
FWCI
3.22
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Can a Tool That Automates Insulin Titration Be a Key to Diabetes Management? https://app.cochat.ai/papers/10.1089/dia.2011.0303
The paper
Bergenstal, R. M., Bashan, E., McShane, M., Johnson, M., & Hodish, I. (2012). Can a Tool That Automates Insulin Titration Be a Key to Diabetes Management? Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2011.0303

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.