CoChat

Standardized Glycemic Management with a Computerized Workflow and Decision Support System for Hospitalized Patients with Type 2 Diabetes on Different Wards

Open access
Neubauer, Katharina M., Mader, Julia K., Höll, Bernhard, Aberer, Felix, Donsa, Klaus, Augustin, Thomas, Schaupp, Lukas, Spat, Stephan, Beck, Peter, Fruhwald, Friedrich M., Schnedl, Christian, Rosenkranz, Alexander R., Lumenta, David B., Kamolz, Lars-Peter, Plank, Johannes, Pieber, Thomas R. · 2015 · Diabetes Technology & Therapeutics
Cited by 51

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: This study investigated the efficacy, safety, and usability of standardized glycemic management by a computerized decision support system for non-critically ill hospitalized patients with type 2 diabetes on four different wards. MATERIALS AND METHODS: In this open, noncontrolled intervention study, glycemic management of 99 patients with type 2 diabetes (62% acute admissions; 41 females; age, 67±11 years; hemoglobin A1c, 65±21 mmol/mol; body mass index, 30.4±6.5 kg/m(2)) on clinical wards (Cardiology, Endocrinology, Nephrology, Plastic Surgery) of a tertiary-care hospital was guided by GlucoTab(®) (Joanneum Research GmbH [Graz, Austria] and Medical University of Graz [Graz, Austria]), a mobile decision support system providing automated workflow support and suggestions for insulin dosing to nurses and physicians. RESULTS: Adherence to insulin dosing suggestions was high (96.5% bolus, 96.7% basal). The primary outcome measure, percentage of blood glucose (BG) measurements in the range of 70-140 mg/dL, occurred in 50.2±22.2% of all measurements. The overall mean BG level was 154±35 mg/dL. BG measurements in the ranges of 60-70 mg/dL, 40-60 mg/dL, and <40 mg/dL occurred in 1.4%, 0.5%, and 0.0% of all measurements, respectively. A regression analysis showed that acute admission to the Cardiology Ward (+30 mg/dL) and preexisting home insulin therapy (+26 mg/dL) had the strongest impact on mean BG. Acute admission to other wards had minor effects (+4 mg/dL). Ninety-one percent of the healthcare professionals felt confident with GlucoTab, and 89% believed in its practicality and 80% in its ability to prevent medication errors. CONCLUSIONS: An efficacious, safe, and user-accepted implementation of GlucoTab was demonstrated. However, for optimized personalized patient care, further algorithm modifications are required.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2015.0027

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 51

Metadata

Authors
Neubauer, K. M., Mader, J. K., Höll, B., Aberer, F., Donsa, K., Augustin, T., Schaupp, L., Spat, S., Beck, P., Fruhwald, F. M., Schnedl, C., Rosenkranz, A. R., Lumenta, D. B., Kamolz, L.-P., Plank, J., & Pieber, T. R.
Venue
Diabetes Technology & Therapeutics
Published
2015-10
Volume
17
Issue
10
Pages
685-692
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2169018261
Cited by
51
References
8
FWCI
4.30
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.