Human Factors Usability and Validation Studies of a Glucagon Autoinjector in a Simulated Severe Hypoglycemia Rescue Situation
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background: A room-temperature stable, soluble liquid glucagon formulation loaded into a prefilled, single-use, two-step autoinjector is under development for severe hypoglycemia rescue. We report a human factors validation program evaluating the glucagon autoinjector (GAI) (Gvoke HypoPen™; Xeris Pharmaceuticals, Inc., Chicago, IL) versus marketed glucagon emergency kits (GEKs) for managing severe hypoglycemia. Methods: A simulated-use human factors usability study was conducted with the GAI versus marketed GEKs in 16 participants, including adult caregivers and first responders, experienced with glucagon administration. A summative human factors validation study of the GAI was conducted with 75 volunteers. Participants were (1) trained on the device and procedure or (2) given time to individually read the instructions and familiarize themselves with the device. Participants returned a week later to perform an unaided rescue attempt that simulated rescue of patients with diabetes suffering a hypoglycemia emergency. Participant actions were recorded for critical rescue tasks and use errors. Results: In the usability study, 88% (14) successfully administered a rescue injection using the GAI versus 31% (5) using GEKs ( P < 0.05). Mean total rescue time of use was 47.9 s with the GAI versus 109.0 s with GEKs ( P < 0.05). In the validation study, 98.7% successfully administered the rescue injection using the GAI. Overall, there were no patterns of differences between trained versus untrained participants, between caregivers versus first responders or between adults versus adolescents. Conclusion: The GAI and instructional materials can be correctly, safely, and effectively used by intended user, which support continued development of the GAI as an alternative to GEKs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wild, D., von Maltzahn, R., Brohan, E., Christensen, T., Clauson, P., & Gonder-Frederick, L. (2007) · Patient Education and Counseling · doi:10.1016/j.pec.2007.05.003 · Cited by 545
Increased mortality of patients with diabetes reporting severe hypoglycemia
McCoy, R. G., Van Houten, H. K., Ziegenfuss, J. Y., Shah, N. D., Wermers, R. A., & Smith, S. A. (2012) · Diabetes Care · doi:10.2337/dc11-2054 · Cited by 539
Hypoglycaemia in Type 2 diabetes
Amiel, S. A., Dixon, T., Mann, R., & Jameson, K. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2007.02341.x · Cited by 472
Assessment and management of hypoglycemia in children and adolescents with diabetes
Clarke, W., Jones, T., Rewers, A., Dunger, D., & Klingensmith, G. J. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2009.00583.x · Cited by 135 · cited 6×
“The objectives of the comparative usability study were to (1) evaluate the intuitiveness, ease of use, and acceptability of the GAI; (2) evaluate the readability and effectiveness of the instructions for use (IFU) and quickuse Label Guide (printed directly on the secondary device packaging) to identify any necessary c…”
BackgroundMethodInfluentialYale, J.-F., Dulude, H., Egeth, M., Piché, C. A., Lafontaine, M., Carballo, D., Margolies, R., Dissinger, E., Shames, A. R., Kaplowitz, N., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0460 · Cited by 88
Brod, M., Rana, A., & Barnett, A. H. (2012) · Current Medical Research and Opinion · doi:10.1185/03007995.2012.743457 · Cited by 60
Mitchell, B. D., He, X., Sturdy, I. M., Cagle, A. P., & Settles, J. A. (2016) · Endocrine Practice · doi:10.4158/ep15831.or · Cited by 46
Christiansen, M. P., Cummins, M., Prestrelski, S., Close, N. C., Nguyen, A., & Junaidi, K. (2021) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2021-002137 · Cited by 22
Self-citation
Cited by
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Bajaj, M., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s009 · Cited by 728
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Gaglia, J. L., Hilliard, M. E., Johnson, E. L., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s009 · Cited by 662
9. pharmacologic approaches to glycemic treatment: standards of care in diabetes—2026
American Diabetes Association Professional Practice Committee for Diabetes*, Bajaj, M., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Briggs Early, K., ChallaSivaKanaka, S., et al. (2026) · Diabetes Care · doi:10.2337/dc26-s009 · Cited by 263
Christiansen, M. P., Cummins, M., Prestrelski, S., Close, N. C., Nguyen, A., & Junaidi, K. (2021) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2021-002137 · Cited by 22
Self-citationPieber, T. R., Aronson, R., Christiansen, M. P., Bode, B., Junaidi, K., & Conoscenti, V. (2022) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14699 · Cited by 8
Metadata
- Authors
- Valentine, V., Newswanger, B., Prestrelski, S., Andre, A. D., & Garibaldi, M.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2019-09-01
- Volume
- 21
- Issue
- 9
- Pages
- 522-530
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2949402067
- Cited by
- 49
- References
- 8
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.