Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 354

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Characteristics of Metals Used in Implants

GOTMAN, IRENA·1997·Journal of Endourology

Abstract

The performance of any material in the human body is controlled by two sets of characteristics: biofunctionality and biocompatibility. With the wide range of materials available in the mid-1990s, it is relatively easy to satisfy the requirements for mechanical and physical functionality of implantable devices. Therefore, the selection of materials for medical applications is usually based on considerations of biocompatibility. When metals and alloys are considered, the susceptibility of the material to corrosion and the effect the corrosion has on the tissue are the central aspects of biocompatibility. Corrosion resistance of the currently used 316L stainless steel, cobalt-chromium, and titanium-based implant alloys relies on their passivation by a thin surface layer of oxide. Stainless steel is the least corrosion resistant, and it is used for temporary implants only. The titanium and Co-Cr alloys do not corrode in the body; however, metal ions slowly diffuse through the oxide layer and accumulate in the tissue. When a metal implant is placed in the human body, it becomes surrounded by a layer of fibrous tissue of a thickness that is proportional to the amount and toxicity of the dissolution products and to the amount of motion between the implant and the adjacent tissues. Pure titanium may elicit a minimal fibrous encapsulation under some conditions, whereas the proliferation of a fibrous layer as much as 2 mm thick is encountered with the use of stainless steel implants. Superior fracture and fatigue resistance have made metals the materials of choice for traditional load-bearing applications. In this review, the functionality of currently used metals and alloys is discussed with respect to stenting applications. In addition, the "shape memory" and "pseudo-elasticity" properties of Nitinol-an alloy that is being considered for the manufacturing of urologic stents-are described.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/end.1997.11.383

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 354

Metadata

Authors
GOTMAN, I.
Venue
Journal of Endourology
Published
1997-12
Volume
11
Issue
6
Pages
383-389
ISSN
  • 0892-7790 (ISSN-L)
  • 1557-900X
OpenAlex
W2091501330
Cited by
354
References
2
FWCI
2.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characteristics of Metals Used in Implants. https://app.cochat.ai/papers/10.1089/end.1997.11.383
The paper
GOTMAN, I. (1997). Characteristics of Metals Used in Implants. Journal of Endourology. https://doi.org/10.1089/end.1997.11.383

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.