The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Characteristics of Metals Used in Implants
Abstract
The performance of any material in the human body is controlled by two sets of characteristics: biofunctionality and biocompatibility. With the wide range of materials available in the mid-1990s, it is relatively easy to satisfy the requirements for mechanical and physical functionality of implantable devices. Therefore, the selection of materials for medical applications is usually based on considerations of biocompatibility. When metals and alloys are considered, the susceptibility of the material to corrosion and the effect the corrosion has on the tissue are the central aspects of biocompatibility. Corrosion resistance of the currently used 316L stainless steel, cobalt-chromium, and titanium-based implant alloys relies on their passivation by a thin surface layer of oxide. Stainless steel is the least corrosion resistant, and it is used for temporary implants only. The titanium and Co-Cr alloys do not corrode in the body; however, metal ions slowly diffuse through the oxide layer and accumulate in the tissue. When a metal implant is placed in the human body, it becomes surrounded by a layer of fibrous tissue of a thickness that is proportional to the amount and toxicity of the dissolution products and to the amount of motion between the implant and the adjacent tissues. Pure titanium may elicit a minimal fibrous encapsulation under some conditions, whereas the proliferation of a fibrous layer as much as 2 mm thick is encountered with the use of stainless steel implants. Superior fracture and fatigue resistance have made metals the materials of choice for traditional load-bearing applications. In this review, the functionality of currently used metals and alloys is discussed with respect to stenting applications. In addition, the "shape memory" and "pseudo-elasticity" properties of Nitinol-an alloy that is being considered for the manufacturing of urologic stents-are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase Transformations in Metals and Alloys
Porter, D. A., & Easterling, K. E. (1992) · doi:10.1007/978-1-4899-3051-4 · Cited by 4,904
Applied General-Equilibrium Models of Taxation and International Trade: An Introduction and Survey
Shoven, J. B., & Whalley, J. (2008) · Journal of Economic Literature · Cited by 897
Cited by
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Kuribayashi, K., Tsuchiya, K., You, Z., Tomus, D., Umemoto, M., Ito, T., & Sasaki, M. (2006) · Materials Science and Engineering: A · doi:10.1016/j.msea.2005.12.016 · Cited by 755
Fabrication of Scaffolds for Bone-Tissue Regeneration
Chocholata, P., Kulda, V., & Babuska, V. (2019) · Materials · doi:10.3390/ma12040568 · Cited by 603
Venezuela, J., & Dargusch, M. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.035 · Cited by 588
Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
Köster, R., Vieluf, D., Kiehn, M., Sommerauer, M., Kähler, J., Baldus, S., Meinertz, T., & Hamm, C. W. (2000) · The Lancet · doi:10.1016/s0140-6736(00)03262-1 · Cited by 530
Metadata
- Authors
- GOTMAN, I.
- Venue
- Journal of Endourology
- Publisher
- SAGE Publications
- Published
- 1997-12
- Volume
- 11
- Issue
- 6
- Pages
- 383-389
- ISSN
- 0892-7790 (ISSN-L)
- 1557-900X
- OpenAlex
- W2091501330
- Cited by
- 354
- References
- 2
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characteristics of Metals Used in Implants. https://app.cochat.ai/papers/10.1089/end.1997.11.383
- The paper
- GOTMAN, I. (1997). Characteristics of Metals Used in Implants. Journal of Endourology. https://doi.org/10.1089/end.1997.11.383
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.