The DOI matches its Crossref record.
Predictors of Incorrect Inhalation Technique in Patients with Asthma or COPD: A Study Using a Validated Videotaped Scoring Method
Abstract
BACKGROUND: Inadequate technique reduces the effects of inhalation medication. Errors in inhalation technique have been reported to range up to 85%. Not only various patients' characteristics but also the device has an effect on correct inhalation technique. The purpose of this study was to determine the effect of patients' characteristics and type of inhaler device on inhalation technique in patient with asthma or chronic obstructive pulmonary disease (COPD). METHODS: A validated scoring method was used that consisted of triple viewing of video-recorded inhalations, using device-specific checklists. The following patient characteristics were investigated: gender, age, education level, diagnosis, treatment by a pulmonary physician, previously received inhalation instruction, exacerbation frequency, knowledge, self-management competence, pulmonary function, and use of multiple inhaler devices. Chi-square statistics were used for univariate associations between potential determinants and correctness of inhalation technique. Relevant determinants were entered into a multivariate logistic regression model. Moreover, inhalation technique errors were examined for six inhaler devices: three prefilled dry powder inhalers, one single-dose dry powder inhaler, a pressurized metered-dose inhaler (pMDI) and a pMDI with a spacer. RESULTS: Overall, 40% of the patients made at least one essential mistake in their inhalation technique. Patients who never received inhalation instruction and patients who used more than one inhaler device made significantly more errors (odds ratio both 2.2). Comparison between devices showed that a correct inhalation technique most likely occurred with the use of prefilled dry powder devices. CONCLUSION: Incorrect inhalation technique is common among asthma and COPD patients in a pulmonary outpatient clinic. Our study suggests that the use of prefilled dry powder inhalers as well as inhalation instruction increases correct inhalation technique. Simultaneous use of different types of inhalation devices has to be discouraged.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vogelmeier, C. F., Criner, G. J., Martinez, F. J., Anzueto, A., Barnes, P. J., Bourbeau, J., Celli, B. R., Chen, R., Decramer, M., Fabbri, L. M., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201701-0218pp · Cited by 3,187
Systematic Review of Errors in Inhaler Use
Sanchis, J., Gich, I., & Pedersen, S. (2016) · CHEST · doi:10.1016/j.chest.2016.03.041 · Cited by 538
Goals of COPD treatment: Focus on symptoms and exacerbations
Vogelmeier, C. F., Román-Rodríguez, M., Singh, D., Han, M. K., Rodríguez-Roisin, R., & Ferguson, G. T. (2020) · Respiratory Medicine · doi:10.1016/j.rmed.2020.105938 · Cited by 371
Vogelmeier, C. F., Criner, G. J., Martínez, F. J., Anzueto, A., Barnes, P. J., Bourbeau, J., Celli, B. R., Chen, R., Decramer, M., Fabbri, L. M., et al. (2017) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2017.02.001 · Cited by 309
Metadata
- Authors
- Rootmensen, G. N., van Keimpema, A. R. J., Jansen, H. M., & de Haan, R. J.
- Venue
- Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Publisher
- SAGE Publications
- Published
- 2010-10
- Volume
- 23
- Issue
- 5
- Pages
- 323-328
- ISSN
- 1941-2703 (ISSN-L)
- 1941-2711
- OpenAlex
- W2096872979
- Cited by
- 231
- References
- 0
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predictors of Incorrect Inhalation Technique in Patients with Asthma or COPD: A Study Using a Validated Videotaped Scoring Method. https://app.cochat.ai/papers/10.1089/jamp.2009.0785
- The paper
- Rootmensen, G. N., van Keimpema, A. R. J., Jansen, H. M., & de Haan, R. J. (2010). Predictors of Incorrect Inhalation Technique in Patients with Asthma or COPD: A Study Using a Validated Videotaped Scoring Method. Journal of Aerosol Medicine and Pulmonary Drug Delivery. https://doi.org/10.1089/jamp.2009.0785
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.