Fabrication of Three-Dimensional Porous Scaffolds of Complicated Shape for Tissue Engineering. I. Compression Molding Based on Flexible–Rigid Combined Mold
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A novel method for the fabrication of complexly shaped three-dimensional porous scaffolds has been developed by combining modified compression molding and conventional particulate leaching. The resultant scaffolds of various shapes, including some shaped like auricles, were made of hydrophobic biodegradable and bioresorbable poly(D,L-lactic acid) (PDLLA) and poly(D,L-lactic-co-glycolic acid) (PLGA). A polymer-particulate mixture was first prepared by the conventional solvent casting method and then compressively molded in a specially designed flexible-rigid combined mold which facilitates shaping and mold release during the fabrication process. The molding was carried out at a moderate temperature, above the glass transition temperature and below the flow temperature of these amorphous polymers. A porous scaffold was then obtained after particulate leaching. The pores are highly interconnected and uniformly distributed both in the bulk and on the external surface of the scaffolds, and the porosity can exceed 90%. The mechanical properties of the resultant porous scaffolds are satisfactory as determined by measurements of compressive modulus and compressive stress at 10% strain. Good viability of cells seeded in the porous scaffolds was confirmed. This novel fabrication method is promising in tissue engineering because of its ability to produce precise and complexly (anatomically) shaped porous scaffolds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Cited by
Injectable hydrogels as unique biomedical materials
Yu, L., & Ding, J. (2008) · Chemical Society Reviews · doi:10.1039/b713009k · Cited by 1,545
Self-citationBone tissue engineering: A review in bone biomimetics and drug delivery strategies
Porter, J. R., Ruckh, T. T., & Popat, K. C. (2009) · Biotechnology Progress · doi:10.1002/btpr.246 · Cited by 809
Biodegradable Polymer Scaffolds with Well-Defined Interconnected Spherical Pore Network
Ma, P. X., & Choi, J.-W. (2001) · Tissue Engineering · doi:10.1089/107632701300003269 · Cited by 620
Cell–Material Interactions Revealed Via Material Techniques of Surface Patterning
Yao, X., Peng, R., & Ding, J. (2013) · Advanced Materials · doi:10.1002/adma.201301762 · Cited by 501
Self-citationPolymer carriers for drug delivery in tissue engineering
Sokolsky-Papkov, M., Agashi, K., Olaye, A., Shakesheff, K., & Domb, A. J. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.04.001 · Cited by 452
Metadata
- Authors
- Wu, L., Zhang, H., Zhang, J., & Ding, J.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2005-07
- Volume
- 11
- Issue
- 7-8
- Pages
- 1105-1114
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W1552789914
- Cited by
- 122
- References
- 1
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.