Characterizing Environmental Factors that Impact the Viability of Tissue-Engineered Constructs Fabricated by a Direct-Write Bioassembly Tool
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Tissue engineering combines the fields of medicine and engineering to build replacement tissue capable of restoring, maintaining, or improving damaged tissue. Researchers have recently developed techniques to fabricate tissue in which both the cells and matrix have a carefully defined architecture. This report details studies evaluating the use of a direct-write, 3-dimensional (3D) bioassembly tool (BAT) capable of extruding cells and matrix into spatially organized, 3D constructs. This system has been characterized by its ability to fabricate viable 2-dimensional and 3D constructs containing up to 2 separate cellular solutions suspended in type I collagen. The effects of various environmental factors, such as extrusion pressure, humidity, and stage heating, were examined with respect to the viability of the extruded cells. The data indicate that the system parameters required to extrude cells suspended in collagen do not adversely affect the viability of those cells. Maintaining a high humidity, especially when stage heat was applied, is critical in maintaining the viability of the printed cells. These results demonstrate that the BAT is capable of spatially organizing separate cellular solutions into a defined architecture; however, when cells were extruded in a supporting matrix of 3.0 mg/mL type I collagen, it was not possible to consistently generate adjacent, touching, but nonoverlapping lines of separate solutions. Thus, when a fabrication system such as BAT is used to generate complex, 3D viable constructs, the supporting matrix for the cells should be carefully chosen on the basis of such characteristics as its rate of polymerization and stiffness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SELF-REGULATION OF GROWTH IN THREE DIMENSIONS
Folkman, J., & Hochberg, M. (1973) · The Journal of Experimental Medicine · doi:10.1084/jem.138.4.745 · Cited by 829 · cited 1×
“22 Thus, a method to provide for nutrient and waste exchange within the constructs will be necessary.”
Cited by
3D bioprinting of tissues and organs
Murphy, S. V., & Atala, A. (2014) · Nature Biotechnology · doi:10.1038/nbt.2958 · Cited by 7,034
3D bioprinting of vascularized, heterogeneous cell-laden tissue constructs
Kolesky, D. B., Truby, R. L., Gladman, A. S., Busbee, T. A., Homan, K. A., & Lewis, J. A. (2014) · Advanced Materials · doi:10.1002/adma.201305506 · Cited by 2,102
25th Anniversary Article: Engineering Hydrogels for Biofabrication
Malda, J., Visser, J., Melchels, F. P., Jüngst, T., Hennink, W. E., Dhert, W. J. A., Groll, J., & Hutmacher, D. W. (2013) · Advanced Materials · doi:10.1002/adma.201302042 · Cited by 1,901
A review of trends and limitations in hydrogel-rapid prototyping for tissue engineering
Billiet, T., Vandenhaute, M., Schelfhout, J., Van Vlierberghe, S., & Dubruel, P. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.04.050 · Cited by 1,284
Tissue engineering by self-assembly and bio-printing of living cells
Jakab, K., Norotte, C., Marga, F., Murphy, K., Vunjak-Novakovic, G., & Forgacs, G. (2010) · Biofabrication · doi:10.1088/1758-5082/2/2/022001 · Cited by 593
Metadata
- Authors
- Smith, C. M., Christian, J. J., Warren, W. L., & Williams, S. K.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2007-02
- Volume
- 13
- Issue
- 2
- Pages
- 373-383
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2047045486
- Cited by
- 116
- References
- 1
- FWCI
- 3.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.