The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A Tissue-Engineered Muscle Repair Construct for Functional Restoration of an Irrecoverable Muscle Injury in a Murine Model
Open accessAbstract
There are no effective clinical treatments for volumetric muscle loss (VML) resulting from traumatic injury, tumor excision, or other degenerative diseases of skeletal muscle. The goal of this study was to develop and characterize a more clinically relevant tissue-engineered muscle repair (TE-MR) construct for functional restoration of a VML injury in the mouse lattissimus dorsi (LD) muscle. To this end, TE-MR constructs developed by seeding rat myoblasts on porcine bladder acellular matrix were preconditioned in a bioreactor for 1 week and implanted in nude mice at the site of a VML injury created by excising 50% of the native LD. Two months postinjury and implantation of TE-MR, maximal tetanic force was ∼72% of that observed in native LD muscle. In contrast, injured LD muscles that were not repaired, or were repaired with scaffold alone, produced only ∼50% of native LD muscle force after 2 months. Histological analyses of LD tissue retrieved 2 months after implantation demonstrated remodeling of the TE-MR construct as well as the presence of desmin-positive myofibers, blood vessels, and neurovascular bundles within the TE-MR construct. Overall, these encouraging initial observations document significant functional recovery within 2 months of implantation of TE-MR constructs and provide clear proof of concept for the applicability of this technology in a murine VML injury model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grogan, B. F., & Hsu, J. R. (2011) · American Academy of Orthopaedic Surgeon · doi:10.5435/00124635-201102001-00007 · Cited by 402
Spector, S. A., Gardiner, P. F., Zernicke, R. F., Roy, R. R., & Edgerton, V. R. (1980) · Journal of Neurophysiology · doi:10.1152/jn.1980.44.5.951 · Cited by 397
Nature of dividing nuclei in skeletal muscle of growing rats
Moss, F. P., & Leblond, C. P. (1970) · The Journal of Cell Biology · doi:10.1083/jcb.44.2.459 · Cited by 289
E-C coupling failure in mouse EDL muscle after in vivo eccentric contractions
Ingalls, C. P., Warren, G. L., Williams, J. H., Ward, C. W., & Armstrong, R. B. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.58 · Cited by 262
Contraction-induced injury: recovery of skeletal muscles in young and old mice
Brooks, S. V., & Faulkner, J. A. (1990) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1990.258.3.c436 · Cited by 238
Excitation failure in eccentric contraction-induced injury of mouse soleus muscle
Warren, G. L., Lowe, D. A., Hayes, D. A., Karwoski, C. J., Prior, B. M., & Armstrong, R. B. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019783 · Cited by 189
Ingalls, C. P., Warren, G. L., & Armstrong, R. B. (1998) · Journal of Muscle Research & Cell Motility · doi:10.1023/a:1005368831198 · Cited by 91
FKBP12 deficiency reduces strength deficits after eccentric contraction-induced muscle injury
Corona, B. T., Rouviere, C., Hamilton, S. L., & Ingalls, C. P. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01145.2007 · Cited by 22
Self-citation
Cited by
Qazi, T. H., Mooney, D. J., Pumberger, M., Geißler, S., & Duda, G. N. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.110 · Cited by 433
Maffioletti, S. M., Sarcar, S., Henderson, A. B. H., Mannhardt, I., Pinton, L., Moyle, L. A., Steele-Stallard, H., Cappellari, O., Wells, K. E., Ferrari, G., et al. (2018) · Cell Reports · doi:10.1016/j.celrep.2018.03.091 · Cited by 337
Costantini, M., Testa, S., Mozetic, P., Barbetta, A., Fuoco, C., Fornetti, E., Tamiro, F., Bernardini, S., Jaroszewicz, J., Święszkowski, W., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.026 · Cited by 330
Quarta, M., Cromie, M., Chacon, R., Blonigan, J., Garcia, V., Akimenko, I., Hamer, M., Paine, P., Stok, M., Shrager, J. B., et al. (2017) · Nature Communications · doi:10.1038/ncomms15613 · Cited by 278
The promotion of a constructive macrophage phenotype by solubilized extracellular matrix
Sicari, B. M., Dziki, J. L., Siu, B. F., Medberry, C. J., Dearth, C. L., & Badylak, S. F. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.06.060 · Cited by 255
Metadata
- Authors
- Machingal, M. A., Corona, B. T., Walters, T. J., Kesireddy, V., Koval, C. N., Dannahower, A., Zhao, W., Yoo, J. J., & Christ, G. J.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2011-09
- Volume
- 17
- Issue
- 17-18
- Pages
- 2291-2303
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W1974517758
- Cited by
- 185
- References
- 8
- FWCI
- 11.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Tissue-Engineered Muscle Repair Construct for Functional Restoration of an Irrecoverable Muscle Injury in a Murine Model. https://app.cochat.ai/papers/10.1089/ten.tea.2010.0682
- The paper
- Machingal, M. A., Corona, B. T., Walters, T. J., Kesireddy, V., Koval, C. N., Dannahower, A., Zhao, W., Yoo, J. J., & Christ, G. J. (2011). A Tissue-Engineered Muscle Repair Construct for Functional Restoration of an Irrecoverable Muscle Injury in a Murine Model. Tissue Engineering Part A. https://doi.org/10.1089/ten.tea.2010.0682
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.