CoChat

A Novel Bioreactor for Stimulating Skeletal Muscle In Vitro

Open access
Donnelly, Kenneth, Khodabukus, Alastair, Philp, Andrew, Deldicque, Louise, Dennis, Robert G., Baar, Keith · 2010 · Tissue Engineering Part C: Methods
Cited by 114

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

For over 300 years, scientists have understood that stimulation, in the form of an electrical impulse, is required for normal muscle function. More recently, the role of specific parameters of the electrical impulse (i.e., the pulse amplitude, pulse width, and work-to-rest ratio) has become better appreciated. However, most existing bioreactor systems do not permit sufficient control over these parameters. Therefore, the aim of the current study was to engineer an inexpensive muscle electrical stimulation bioreactor to apply physiologically relevant electrical stimulation patterns to tissue-engineered muscles and monolayers in culture. A low-powered microcontroller and a DC-DC converter were used to power a pulse circuit that converted a 4.5 V input to outputs of up to 50 V, with pulse widths from 0.05 to 4 ms, and frequencies up to 100 Hz (with certain operational limitations). When two-dimensional cultures were stimulated at high frequencies (100 Hz), this resulted in an increase in the rate of protein synthesis (at 12 h, control [CTL] = 5.0 + or - 0.16; 10 Hz = 5.0 + or - 0.07; and 100 Hz = 5.5 + or - 0.13 fmol/min/mg) showing that this was an anabolic signal. When three-dimensional engineered muscles were stimulated at 0.1 ms and one or two times rheobase, stimulation improved force production (CTL = 0.07 + or - 0.009; 1.25 V/mm = 0.10 + or - 0.011; 2.5 V/mm = 0.14146 + or - 0.012; and 5 V/mm = 0.03756 + or - 0.008 kN/mm(2)) and excitability (CTL = 0.53 + or - 0.022; 1.25 V/mm = 0.44 + or - 0.025; 2.5 V/mm = 0.41 + or - 0.012; and 5 V/mm = 0.60 + or - 0.021 V/mm), suggesting enhanced maturation. Together, these data show that the physiology and function of muscles can be improved in vitro using a bioreactor that allows the control of pulse amplitude, pulse width, pulse frequency, and work-to-rest ratio.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tec.2009.0125

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 114

Metadata

Authors
Donnelly, K., Khodabukus, A., Philp, A., Deldicque, L., Dennis, R. G., & Baar, K.
Venue
Tissue Engineering Part C: Methods
Published
2010-08
Volume
16
Issue
4
Pages
711-718
ISSN
  • 1937-3384 (ISSN-L)
  • 1937-3392
OpenAlex
W2022826364
Cited by
114
References
1
FWCI
4.61
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Bioreactor for Stimulating Skeletal Muscle In Vitro. https://app.cochat.ai/papers/10.1089/ten.tec.2009.0125
The paper
Donnelly, K., Khodabukus, A., Philp, A., Deldicque, L., Dennis, R. G., & Baar, K. (2010). A Novel Bioreactor for Stimulating Skeletal Muscle In Vitro. Tissue Engineering Part C: Methods. https://doi.org/10.1089/ten.tec.2009.0125

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.