The DOI matches its Crossref record.
Role of Thyroglobulin Measurement in Fine-Needle Aspiration Biopsies of Cervical Lymph Nodes in Patients with Differentiated Thyroid Cancer
Abstract
The identification of metastatic neck lymph nodes in patients awaiting surgery for differentiated thyroid tumor permits their excision during thyroidectomy. In order to detect thyroid cancer lymphatic metastasis before surgery, we measured thyroglobulin (Tg) in the needle wash-out of fine-needle aspiration biopsy (FNAB). Ultrasound-guided FNAB on enlarged neck nodes was performed in 23 patients awaiting surgery for differentiated thyroid tumor (n = 33 lymph nodes), 47 patients previously thyroidectomized for thyroid tumor (n = 89 lymph nodes), and 60 patients without thyroid disease (n = 94 lymph nodes). Immediately after aspiration biopsy, the needle was rinsed with 1 mL of normal saline solution and Tg levels were measured on the needle wash-out (FNAB-Tg). FNAB-Tg levels were markedly elevated in metastatic lymph nodes both in patients awaiting thyroidectomy (metastatic vs. negative lymph nodes, mean +/- SEM, 16,593 +/- 7,050 ng/mL vs. 4.91 +/- 1.61 ng/mL; p < 0.001) and in thyroidectomized patients (11,541 +/- 7,283 ng/mL vs. 0.45 +/- 0.07 ng/mL; p < 0.001). FNAB-Tg sensitivity, evaluated through histological examination in 69 lymph nodes, was 84.0%. The combination of cytology plus FNAB-Tg increased FNAB sensitivity from 76% to 92.0%. In conclusion, FNAB-Tg measurement is a useful technique for early diagnosis of lymph node metastasis originating from differentiated thyroid cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Haugen, B. R., Alexander, E. K., Bible, K. C., Doherty, G. M., Mandel, S. J., Nikiforov, Y. E., Pacini, F., Randolph, G. W., Sawka, A. M., Schlumberger, M., et al. (2016) · Thyroid® · doi:10.1089/thy.2015.0020 · Cited by 16,535
Ringel, M. D., Sosa, J. A., Baloch, Z., Bischoff, L., Bloom, G., Brent, G. A., Brock, P. L., Chou, R., Flavell, R. R., Goldner, W., et al. (2025) · Thyroid® · doi:10.1177/10507256251363120 · Cited by 710
Giordano, D., Valcavi, R., Thompson, G. B., Pedroni, C., Renna, L., Gradoni, P., & Barbieri, V. (2012) · Thyroid · doi:10.1089/thy.2012.0011 · Cited by 400
Self-citationPapillary Microcarcinoma of the Thyroid: How Should It Be Treated?
Ito, Y., Tomoda, C., Uruno, T., Takamura, Y., Miya, A., Kobayashi, K., Matsuzuka, F., Kuma, K., & Miyauchi, A. (2004) · World Journal of Surgery · doi:10.1007/s00268-004-7644-5 · Cited by 296
Thyroglobulin measurement in the management of patients with differentiated thyroid cancer
Algeciras-Schimnich, A. (2018) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1450830 · Cited by 63
Metadata
- Authors
- FRASOLDATI, A., TOSCHI, E., ZINI, M., FLORA, M., CAROGGIO, A., DOTTI, C., & VALCAVI, R.
- Venue
- Thyroid
- Publisher
- SAGE Publications
- Published
- 1999-02
- Volume
- 9
- Issue
- 2
- Pages
- 105-111
- ISSN
- 1050-7256 (ISSN-L)
- 1557-9077
- OpenAlex
- W2062963159
- Cited by
- 172
- References
- 0
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Role of Thyroglobulin Measurement in Fine-Needle Aspiration Biopsies of Cervical Lymph Nodes in Patients with Differentiated Thyroid Cancer. https://app.cochat.ai/papers/10.1089/thy.1999.9.105
- The paper
- FRASOLDATI, A., TOSCHI, E., ZINI, M., FLORA, M., CAROGGIO, A., DOTTI, C., & VALCAVI, R. (1999). Role of Thyroglobulin Measurement in Fine-Needle Aspiration Biopsies of Cervical Lymph Nodes in Patients with Differentiated Thyroid Cancer. Thyroid. https://doi.org/10.1089/thy.1999.9.105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.