CoChat

Improved Radioimmunoassay for Measurement of Mouse Thyrotropin in Serum: Strain Differences in Thyrotropin Concentration and Thyrotroph Sensitivity to Thyroid Hormone

POHLENZ, JOACHIM, MAQUEEM, AHMED, CUA, KEVIN, WEISS, ROY E., VAN SANDE, JACQUELINE, REFETOFF, SAMUEL · 1999 · Thyroid
Cited by 154

The DOI matches its Crossref record.

Abstract

We report an improved heterologous radioimmunoassay (RIA) for the measurement of thyrotropin (TSH) in mouse serum. The assay components are: antirat thyrotropin (rTSH) serum from the National Hormone and Pituitary Program, a commercial [125I]-labeled rTSH and mouse thyrotropin (mTSH) serum standards produced by dilution of a serum pool from hypothyroid mice with high TSH with a serum pool from mice treated with excess levothyroxine (LT4) (mTSH-0). Sensitivity was increased by reducing the amount of antibody and tracer and by taking advantage of the disequilibrium technique. Accuracy was greatly improved by the preparation of mouse serum TSH standards. TSH in serial dilutions of individual mice with high TSH of different etiologies paralleled the mTSH standard curve but not that of rTSH or a crude mouse TSH/luteinizing hormone (LH) reference preparation. The high-mTSH-serum standard contained 20 mU TSH per milliliter, measured in a bioassay utilizing a cell line stably transfected with human TSH receptor cDNA, and a relative TSH concentration of 40 ng/mL. The sensitivity of the RIA is 0.01 to 0.02 ng/mL, depending on the quality of the tracer and the preparation of mTSH-0 serum. The intra-assay and interassay coefficients of variations were, respectively: 16% and 27% at 0.04 ng/mL; 6.3% and 8.2% at 0.4 ng/mL; 5.4% and 9.8% at 1.7 ng/mL; 10% and 24% at 4.0 ng/mL. The mean TSH concentration in serum of 60-80-day-old male mice was four-fold higher than that in females of the same age. The assay was able to distinguish differences in serum TSH concentrations in five different strains of mice. Baseline serum TSH concentrations (mean +/- SD) of 70-day-old male mice were: 0.143 +/- 0.065 ng/mL in the CD-1 strain; 0.229 +/- 0.042 ng/mL in C57BL/6 mice; 0.084 +/- 0.017 ng/mL in SWR/J mice; 0.133 +/- 0.057 ng/mL in NOD SCID mice, and 0.266 +/- 0.122 ng/mL in FVB mice. Mean serum thyroxine (T4) concentrations were also significantly different among the mouse strains but did not correlate with the serum TSH level. Administration of levotriiodothyronine (LT3) suppressed the serum TSH to a greater degree in mice with higher baseline TSH values. Suppression of the thyroidal radioiodide uptake with LT3 correlated with that of serum TSH.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/thy.1999.9.1265

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 154

Metadata

Authors
POHLENZ, J., MAQUEEM, A., CUA, K., WEISS, R. E., VAN SANDE, J., & REFETOFF, S.
Venue
Thyroid
Published
1999-12
Volume
9
Issue
12
Pages
1265-1271
ISSN
  • 1050-7256 (ISSN-L)
  • 1557-9077
OpenAlex
W2019259772
Cited by
154
References
0
FWCI
3.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved Radioimmunoassay for Measurement of Mouse Thyrotropin in Serum: Strain Differences in Thyrotropin Concentration and Thyrotroph Sensitivity to Thyroid Hormone. https://app.cochat.ai/papers/10.1089/thy.1999.9.1265
The paper
POHLENZ, J., MAQUEEM, A., CUA, K., WEISS, R. E., VAN SANDE, J., & REFETOFF, S. (1999). Improved Radioimmunoassay for Measurement of Mouse Thyrotropin in Serum: Strain Differences in Thyrotropin Concentration and Thyrotroph Sensitivity to Thyroid Hormone. Thyroid. https://doi.org/10.1089/thy.1999.9.1265

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.