Radiofrequency Ablation of Benign Cold Thyroid Nodules: Initial Clinical Experience
Abstract
CONTEXT AND OBJECTIVE: To evaluate the efficacy and safety of ultrasound (US)-guided percutaneous radiofrequency (RF) ablation for benign cold thyroid nodules as a nonsurgical therapeutic modality. DESIGN, INTERVENTION, AND PATIENTS: A total of 35 benign cold thyroid nodules in 30 euthyroid patients (M:F = 2:28; mean age 39.1 years) underwent percutaneous RF ablation with a 1-cm-internally cooled electrode. Seventy-seven percent (23/30) of patients required conscious sedation for discomfort. We evaluated the tumor size, cystic component, vascularity (by color Doppler US), and the severity of mass-related symptoms before treatment. We assessed the therapeutic efficacy and safety of RF ablation by clinical and US follow-up (median 6.4 months). MAIN OUTCOME AND RESULTS: The volume of the tumors before ablation had a range of 0.6-28.2 mL (mean, 6.3 mL). The residual volume was 53.5% +/- 26.5% of original at 1.1-2.9 months (n = 32), 36.2% +/- 27.4% at 3.0-5.9 months (n = 20), 30.7% +/- 25.0% at 6.0-8.9 months (n = 15), and 11.8% +/- 10.9% at 9.0-18.5 months (n = 13). Mixed/mainly cystic tumors showed a significantly better response than mainly solid tumors (p < 0.05). Difference in vascularity did not affect the treatment response. Thyroid function after the procedure was maintained as normal in all patients. Eighty-eight percent of the patients reported an improvement of their symptoms. There was no major complication other than vocal cord palsy in one patient (3.3%). CONCLUSION: RF ablation may be an effective and safe nonsurgical technique to treat benign cold thyroid nodules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Radiofrequency ablation of benign thyroid nodules: safety and imaging follow-up in 236 patients
Jeong, W. K., Baek, J. H., Rhim, H., Kim, Y. S., Kwak, M. S., Jeong, H. J., & Lee, D. (2008) · European Radiology · doi:10.1007/s00330-008-0880-6 · Cited by 473
Self-citationNa, D. G., Lee, J. H., Jung, S. L., Kim, J.-H., Sung, J. Y., Shin, J. H., Kim, E.-K., Lee, J. H., Kim, D. W., Park, J. S., et al. (2012) · Korean Journal of Radiology · doi:10.3348/kjr.2012.13.2.117 · Cited by 337
Self-citationSpiezia, S., Garberoglio, R., Milone, F., Ramundo, V., Caiazzo, C., Assanti, A. P., Deandrea, M., Limone, P. P., Macchia, P. E., Lombardi, G., et al. (2009) · Thyroid · doi:10.1089/thy.2008.0202 · Cited by 277
Complications Following Radiofrequency Ablation of Benign Thyroid Nodules: A Systematic Review
Wang, J.-F., Wu, T., Hu, K.-P., Xu, W., Zheng, B.-W., Tong, G., Yao, Z.-C., Liu, B., & Ren, J. (2017) · Chinese Medical Journal · doi:10.4103/0366-6999.206347 · Cited by 93
Wang, N., Zheng, B., Wu, T., Tan, L., Lian, Y., Ma, Y., Guo, R., Xu, S., Zeng, L., Xu, W., et al. (2021) · International Journal of Hyperthermia · doi:10.1080/02656736.2021.1950849 · Cited by 31
Metadata
- Authors
- Kim, Y.-S., Rhim, H., Tae, K., Park, D. W., & Kim, S. T.
- Venue
- Thyroid
- Publisher
- SAGE Publications
- Published
- 2006-04
- Volume
- 16
- Issue
- 4
- Pages
- 361-367
- ISSN
- 1050-7256 (ISSN-L)
- 1557-9077
- OpenAlex
- W2091200159
- Cited by
- 276
- References
- 0
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiofrequency Ablation of Benign Cold Thyroid Nodules: Initial Clinical Experience. https://app.cochat.ai/papers/10.1089/thy.2006.16.361
- The paper
- Kim, Y.-S., Rhim, H., Tae, K., Park, D. W., & Kim, S. T. (2006). Radiofrequency Ablation of Benign Cold Thyroid Nodules: Initial Clinical Experience. Thyroid. https://doi.org/10.1089/thy.2006.16.361
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.