Standardization of a Bioassay for Thyrotropin Receptor Stimulating Autoantibodies

Diana, Tanja, Kanitz, Michael, Lehmann, Markus, Li, Yunsheng, Olivo, Paul D., Kahaly, George J. · 2015 · Thyroid
Cited by 68

The DOI matches its Crossref record.

Abstract

BACKGROUND: Cell-based bioassays for functional thyroid stimulating autoantibodies (TSAb) are sensitive diagnostic tools. However, there is no bioassay available that is standardized with international reference material. We aimed to promote the standardization of the test results among laboratories that perform TSAb bioassays and calibrate TSAb levels against the second international standard (IS) 08/204 from the National Institute for Biological Standards and Control (NIBSC). METHODS: Serum TSAb activity was measured with a FDA-cleared bioassay that utilizes CHO cells expressing a chimeric thyrotropin receptor (TSHR) and a c-AMP response-element-dependent luciferase. The IS was applied for calibration. TSAb results were reported as percentage of specimen-to-reference ratio (SRR%) and converted into mIU/L. RESULTS: The IS dose-response curve was obtained using concentrations from 0.3125 to 200 mIU/L. Mean TSAb SRR%±standard deviation (SD) values for the IS concentrations 0.3125, 0.625, 1.25, 2.5, 5, 10, 20, 40, 60, 80, 100, 120, 160, and 200 mIU/L were 63±4 (CV 6.3%), 63±4 (6.3), 67±2 (3.0), 76±6 (7.9), 91±8 (8), 134±8 (5.9), 201±13 (6.5), 294±12 (4.1), 336±10 (3.0), 348±8 (2.3), 360±14 (3.8), 371±15 (4.0), 381±9 (2.4), and 389±10 (2.6), respectively. A total of 127 dilution experiments were performed using 12 high TSAb-positive sera from patients with Graves' disease. When diluting TSAb-positive sera, IS concentrations within the linear range 5, 10, 20, 40, and 80 mIU/L were used for the calibration curve. All standard curves had R(2) values >0.95. Low coefficient of variation (CV %) values for the IS calibration curve (4-6%) were obtained. Compared to bovine TSH, no significant differences were noted using either a pool of healthy donors or a normal serum as reference controls. The average IU measured value for the assay cutoff (SRR 140%) corresponded to 9.54±1.68 mIU/L, and clinical application was shown in 60 Graves' patients. CONCLUSIONS: The TSAb bioassay demonstrated excellent performance in terms of linear range, limit of quantitation, and imprecision. The dilution experiments showed a high correlation coefficient and excellent reproducibility. Thus, TSAb levels can be reliably converted from SRR% to IU/L. These results offer the perspective of standardizing TSAb levels among laboratories and enable more accurate comparison of TSAb studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/thy.2014.0346

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 68

Metadata

Authors
Diana, T., Kanitz, M., Lehmann, M., Li, Y., Olivo, P. D., & Kahaly, G. J.
Venue
Thyroid
Published
2015-02
Volume
25
Issue
2
Pages
169-175
ISSN
  • 1050-7256 (ISSN-L)
  • 1557-9077
OpenAlex
W1958761029
Cited by
68
References
0
FWCI
5.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standardization of a Bioassay for Thyrotropin Receptor Stimulating Autoantibodies. https://app.cochat.ai/papers/10.1089/thy.2014.0346
The paper
Diana, T., Kanitz, M., Lehmann, M., Li, Y., Olivo, P. D., & Kahaly, G. J. (2015). Standardization of a Bioassay for Thyrotropin Receptor Stimulating Autoantibodies. Thyroid. https://doi.org/10.1089/thy.2014.0346

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.