Evaluation of a Novel Ambulatory Device for Screening of Sleep Apnea
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The gold standard for diagnosis of obstructive sleep apnea (OSA) is the sleep laboratory polysomnography, which is technically demanding, labor-intensive, and time-consuming. Thus, screening of large undiagnosed population for OSA may be cost efficient only by means of ambulatory devices suitable for home recordings. The aim of our study was to evaluate the diagnostic and technical reliability of a novel ambulatory device (APV2, Remote Analysis Oy) introduced for sleep apnea diagnostics. APV2 records breathing movements, nasal and oral air flow, position, snore, blood oxygen saturation, and heart rate. The evaluation was done by comparing 10 simultaneous polygraphic recordings with APV2 and with commonly used clinical reference instrumentation (Embla, Embla Co.) at a sleep laboratory. Furthermore, the technical reliability of measurements was evaluated by analyzing the fraction of clinical APV2 and Embletta (Embla Co.) home recordings (n = 149 and n = 169, respectively) that were technically of diagnostically unacceptable quality. Similar diagnostic sensitivity in detecting OSA was found with the APV2 compared to the simultaneous reference recording with the Embla. Apnea-hypopnea indices and oxygen desaturation indices, recorded with APV2 and Embla, were closely correlated (r = 0.996-0.997, p < 0.0001). The quality of 90.0% of home recordings with APV2 was technically perfect and 96.0% of recordings were of diagnostically acceptable quality. As a comparison, the clinical evaluation of a widely used ambulatory polygraphy device (Embletta) showed that 77.2% of home recordings were technically perfect and 80.8% of recordings were diagnostically acceptable. In conclusion, the novel device was found clinically applicable, technically reliable, and sensitive for the diagnostics of OSA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Young, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Cited by
Sharma, R. A., Varga, A. W., Bubu, O. M., Pirraglia, E., Kam, K., Parekh, A., Wohlleber, M., Miller, M. D., Andrade, A., Lewis, C., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201704-0704oc · Cited by 245
El Shayeb, M., Topfer, L.-A., Stafinski, T., Pawluk, L., & Menon, D. (2014) · Canadian Medical Association Journal · doi:10.1503/cmaj.130952 · Cited by 237
Chernyshev, O. Y., McCarty, D. E., Moul, D. E., Liendo, C., Caldito, G. C., Munjampalli, S. K., Kelley, R., & Chesson Jr, A. L. (2015) · Nature and Science of Sleep · doi:10.2147/nss.s85780 · Cited by 23
Santos, R. B., Silva, W. A., Parise, B. K., Giatti, S., Aielo, A. N., Souza, S. P., Santos, I. S., Lotufo, P. A., Bensenor, I. M., & Drager, L. F. (2019) · Sleep Medicine · doi:10.1016/j.sleep.2019.04.020 · Cited by 12
Metadata
- Authors
- Tiihonen, P., Hukkanen, T., Tuomilehto, H., Mervaala, E., & Töyräs, J.
- Venue
- Telemedicine and e-Health
- Publisher
- SAGE Publications
- Published
- 2009-04
- Volume
- 15
- Issue
- 3
- Pages
- 283-289
- ISSN
- 1530-5627 (ISSN-L)
- 1556-3669
- OpenAlex
- W1993272149
- Cited by
- 38
- References
- 3
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.