Cited by 16Cardiac pacing and defibrillation studiesTelemedicine and Telehealth ImplementationHealthcare Technology and Patient Monitoring

Clinical and Economic Impact of Remote Monitoring on the Follow-Up of Patients with Implantable Electronic Cardiovascular Devices: An Observational Study

Costa, Paulo Dias, Reis, A. Hipólito, Rodrigues, Pedro P.·2013·Telemedicine and e-Health

Abstract

Traditional follow-up of patients with cardiovascular devices is still an activity that, in addition to serving an increasing population, requires a considerable amount of time and specialized human and technical resources. Our aim was to evaluate the applicability of the CareLink(®) (Medtronic, Minneapolis, MN) remote monitoring system as a complementary option to the follow-up of patients with implanted devices, between in-office visits. Evaluated outcomes included both clinical (event detection and time to diagnosis) and nonclinical (patient's satisfaction and economic costs) aspects. An observational, longitudinal, prospective study was conducted with patients from a Portuguese central hospital sampled by convenience during 1 week (43 patients). Data were collected in four moments: two in-office visits and two remote evaluations, reproducing 1 year of clinical follow-up. Data sources included health records, implant reports, initial demographic data collection, follow-up printouts, and a questionnaire. After selection criteria were verified, 15 patients (11 men [73%]) were included, 63.4±10.8 years old, representing 14.0±6.3 implant months. Clinically, 15 events were detected (9 by remote monitoring and 6 by patient-initiated activation), of which only 9 were symptomatic. We verified that remote monitoring could detect both symptomatic and asymptomatic events, whereas patient-initiated activation only detected symptomatic ones (p=0.028). Moreover, the mean diagnosis anticipation in patients with events was approximately 58 days (p<0.001). In nonclinical terms, we observed high or very high satisfaction (67% and 33%, respectively) with using remote monitoring technology, but still 8 patients (53%) stated they preferred in-office visits. Finally, the introduction of remote monitoring technology has the ability to reduce total follow-up costs for patients by 25%. We conclude that the use of this system constitutes a viable complementary option to the follow-up of patients with implantable devices, between in-office visits.

Integrity signals

Registry

Crossref · 10.1089/tmj.2012.0064

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In a study of patients with implantable cardiovascular devices (n = 43), remote monitoring decreased healthcare costs by 25%.

    “In a study involving patients with implantable cardiovascular devices (n = 43), remote monitoring decreased healthcare costs for those patients by 25% [133].”

    From Wearables and the Medical Revolution (2018) · cites this paper as [133]

The citation lists haven’t been fetched yet

References 22 · Cited by 16

Authors
Costa, P. D., Reis, A. H., & Rodrigues, P. P.
Affiliations
  • Hospital de Santo António (PT)
  • Universidade do Porto (PT)
Corresponding author
Costa, Paulo Dias
Venue
Telemedicine and e-Health
Published
2013-02
Volume
19
Issue
2
Pages
71-80
ISSN
  • 1530-5627 (ISSN-L)
  • 1556-3669
OpenAlex
W2094437474
Cited by
16
References
22
Citations by year
2026: 2 · 2022: 3 · 2020: 1 · 2018: 1 · 2017: 4 · 2016: 3 · 2015: 1 · 2013: 1
FWCI
1.14
Type
journal article
Language
en
Open access
closed
Locations
  • Telemedicine Journal and e-Health (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
Keywords
remote monitoring, device follow-up, event detection, time to diagnosis, patient satisfaction, follow-up costs, economic impact
MeSH terms
Aged, Aged, 80 and over, Arrhythmias, Cardiac, Female, Follow-Up Studies, Humans, Longitudinal Studies, Male, Middle Aged, Pacemaker, Artificial, Portugal, Prospective Studies, Surveys and Questionnaires, Telemetry, Patient Satisfaction, Defibrillators, Implantable

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review