Interactions between CLIP-170, Tubulin, and Microtubules: Implications for the Mechanism of CLIP-170 Plus-End Tracking Behavior
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
CLIP-170 belongs to a group of proteins (+TIPs) with the enigmatic ability to dynamically track growing microtubule plus-ends. CLIP-170 regulates microtubule dynamics in vivo and has been implicated in cargo-microtubule interactions in vivo and in vitro. Though plus-end tracking likely has intimate connections to +TIP function, little is known about the mechanism(s) by which this dynamic localization is achieved. Using a combination of biochemistry and live cell imaging, we provide evidence that CLIP-170 tracks microtubule plus-ends by a preassociation, copolymerization, and regulated release mechanism. As part of this analysis, we find that CLIP-170 has a stronger affinity for tubulin dimer than for polymer, and that CLIP-170 can distinguish between GTP- and GDP-like polymer. This work extends the previous analysis of CLIP-170 behavior in vivo and complements the existing fluorescence microscope characterization of CLIP-170 interactions with microtubules in vitro. In particular, these data explain observations that CLIP-170 localizes to newly polymerized microtubules in vitro but cannot track microtubule plus-ends in vitro. These observations have implications for the functions of CLIP-170 in regulating microtubule dynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tau protein binds to microtubules through a flexible array of distributed weak sites.
Butner, K. A., & Kirschner, M. W. (1991) · The Journal of cell biology · doi:10.1083/jcb.115.3.717 · Cited by 550
Cited by
Tracking the ends: a dynamic protein network controls the fate of microtubule tips
Akhmanova, A., & Steinmetz, M. O. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2369 · Cited by 1,047
“Besides interacting with the microtubule ends, some +TIPs (such as mammalian CLIPs) can bind to tubulin dimers and oligomers in vitro”
BackgroundThe Global Phosphorylation Landscape of SARS-CoV-2 Infection
Bouhaddou, M., Memon, D., Meyer, B., White, K. M., Rezelj, V. V., Correa Marrero, M., Polacco, B. J., Melnyk, J. E., Ulferts, S., Kaake, R. M., et al. (2020) · Cell · doi:10.1016/j.cell.2020.06.034 · Cited by 1,020
Molecular Interaction Studies Using Microscale Thermophoresis
Jerabek-Willemsen, M., Wienken, C. J., Braun, D., Baaske, P., & Duhr, S. (2011) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2011.0380 · Cited by 812
Microtubules and Microtubule-Associated Proteins
Goodson, H. V., & Jonasson, E. M. (2018) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a022608 · Cited by 579
Self-citationAssembly dynamics of microtubules at molecular resolution
Kerssemakers, J. W. J., Laura Munteanu, E., Laan, L., Noetzel, T. L., Janson, M. E., & Dogterom, M. (2006) · Nature · doi:10.1038/nature04928 · Cited by 550
Metadata
- Authors
- Folker, E. S., Baker, B. M., & Goodson, H. V.
- Venue
- Molecular Biology of the Cell
- Published
- 2005-11
- Volume
- 16
- Issue
- 11
- Pages
- 5373-5384
- ISSN
- 1059-1524 (ISSN-L)
- 1939-4586
- OpenAlex
- W2166722620
- Cited by
- 82
- References
- 1
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interactions between CLIP-170, Tubulin, and Microtubules: Implications for the Mechanism of CLIP-170 Plus-End Tracking Behavior. https://app.cochat.ai/papers/10.1091/mbc.e04-12-1106
- The paper
- Folker, E. S., Baker, B. M., & Goodson, H. V. (2005). Interactions between CLIP-170, Tubulin, and Microtubules: Implications for the Mechanism of CLIP-170 Plus-End Tracking Behavior. Molecular Biology of the Cell. https://doi.org/10.1091/mbc.e04-12-1106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.