Simultaneous EEG and fMRI: Recording, Analysis, and Application
The DOI matches its Crossref record.
Abstract
Systemic interactions in brain networks have been successfully studied in vivo using non-invasive methods such as electroencephalography (EEG) and functional magnetic resonance imaging (fMRI), for many years. The rate-limiting step, however, is that each method can only map selective aspects of brain function, while missing other key aspects. Furthermore, the inferences on neuronal processes and information flow are often rather indirect. By simultaneously combining both methods, the researcher is better able to make optimal use of their specific advantages while compensating for their disadvantages. In recent years, research has shifted and expanded, from demonstrating technical feasibility, to methodological issues of artifact control, new ways of analyzing and integrating data, and to applications for scientific and clinical questions. Combined EEG and fMRI methods now cover everything from physiological questions on the bases of the two recorded signals, to more specific questions on the mechanisms of certain cognitive and pathological functions like epileptic brain activity. Simultaneous EEG and fMRI provides the interested researcher with the tools to establish a simultaneous EEG-fMRI laboratory, as well as for those scientists who are interested in integrating electrophysiological and hemodynamic data. As evidenced by the diversity of topics presented, this is a dynamically developing field in which several approaches are being tested, validated, and compared. Chapters are dedicated to the physiological bases of the measured signals, technical setup, sources of artifacts and data de-noising, various approaches of data analysis and fusion, as well as applications. In addition, open questions and directions for future research are outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lonsdorf, T. B., Menz, M. M., Andreatta, M., Fullana, M. A., Golkar, A., Haaker, J., Heitland, I., Hermann, A., Kuhn, M., Kruse, O., et al. (2017) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2017.02.026 · Cited by 837
“For EEG/EMG/startle data (e.g. Lindner et al., 2015), imaging rtefact removal is indispensable and can be achieved through umerous methods and software (Allen et al., 1998, 2000; Garreffa t al., 2003; Mantini et al., 2007; Niazy et al., 2005; Ritter et al., 007; Ullsperger and Debener, 2010).”
Towards the utilization of EEG as a brain imaging tool
Michel, C. M., & Murray, M. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.039 · Cited by 738
Neurophysiology of performance monitoring and adaptive behavior
Ullsperger, M., Danielmeier, C., & Jocham, G. (2014) · Physiological Reviews · doi:10.1152/physrev.00041.2012 · Cited by 634
Tian, L., Zimmerman, B., Akhtar, A., Yu, K. J., Moore, M., Wu, J., Larsen, R. J., Lee, J. W., Li, J., Liu, Y., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0347-x · Cited by 393
Tensor decomposition of EEG signals: A brief review
Cong, F., Lin, Q.-H., Kuang, L.-D., Gong, X.-F., Astikainen, P., & Ristaniemi, T. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.03.018 · Cited by 334
Metadata
- Publisher
- Oxford University PressNew York
- Published
- 2010-04-30
- OpenAlex
- W2121973561
- Cited by
- 133
- References
- 0
- FWCI
- 3.74
- Type
- book
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous EEG and fMRI: Recording, Analysis, and Application. https://app.cochat.ai/papers/10.1093/acprof:oso/9780195372731.001.0001
- The paper
- Simultaneous EEG and fMRI: Recording, Analysis, and Application. (2010). https://doi.org/10.1093/acprof%3Aoso/9780195372731.001.0001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.