The DOI matches its Crossref record.
Immunophenotyping of Acute Leukemia by Flow Cytometric Analysis:Use of CD45 and Right-Angle Light Scatter to Gate on Leukemic Blasts in Three-Color Analysis
Abstract
This article describes a procedure for performing routine three-color flow cytometric analysis for acute leukemia on lysed whole bone marrow preparations. This technique uses the combination of CD45 intensity and right-angle light scatter (RALS) to distinguish leukemic cells from normal lymphocytes, monocytes, neutrophils, eosinophils, and nucleated red blood cells. On this display, leukemic cells occupy a unique blast region characterized by intermediate CD45 density and low RALS, which, in normal marrows, contains less than 5% of the total cells. This approach was applied to 39 cases of acute leukemia and 8 cases of myelodysplasia or myeloproliferative disorders. The estimate of blasts by flow cytometric analysis was correlated highly with morphologic leukemic cell counts over a wide range. Moreover, the pattern seen on the CD45-RALS display was different for different French-American-British subtypes of leukemia, suggesting that this pattern might be useful for categorization. When CD45-peridin chlorophyll alpha protein was combined with other pairs of fluorescein isothiocyanate- and phycoerythrin-conjugated reagents, it was possible to set an analysis window on the leukemic blasts and display dual-parameter (ie, green vs. red fluorescence) data regarding expression of two additional markers on the leukemic population. This gating strategy was superior to traditional forward-angle versus RALS displays in that it did a better job of isolating the leukemic cells analytically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The ISHAGE Guidelines for CD34+ Cell Determination by Flow Cytometry
SUTHERLAND, D. R., ANDERSON, L., KEENEY, M., NAYAR, R., & CHIN-YEE, I. (1996) · Journal of Hematotherapy · doi:10.1089/scd.1.1996.5.213 · Cited by 1,275
on behalf of the EuroFlow Consortium (EU-FP6, L.-C.-2.-0., van Dongen, J. J. M., Lhermitte, L., Böttcher, S., Almeida, J., van der Velden, V. H. J., Flores-Montero, J., Rawstron, A., Asnafi, V, Lécrevisse, Q., et al. (2012) · Leukemia · doi:10.1038/leu.2012.120 · Cited by 934
Recent Advances in Flow Cytometry: Application to the Diagnosis of Hematologic Malignancy
Jennings, C. D., & Foon, K. A. (1997) · Blood · doi:10.1182/blood.v90.8.2863 · Cited by 447
Wells, D. A., Benesch, M., Loken, M. R., Vallejo, C., Myerson, D., Leisenring, W. M., & Deeg, H. J. (2003) · Blood · doi:10.1182/blood-2002-09-2768 · Cited by 358
van der Velden, V. H. J., te Marvelde, J. G., Hoogeveen, P. G., Bernstein, I. D., Houtsmuller, A. B., Berger, M. S., & van Dongen, J. J. M. (2001) · Blood · doi:10.1182/blood.v97.10.3197 · Cited by 338
Metadata
- Authors
- Borowitz, M. J., Lynn Guenther, K., Shults, K. E., & Stelzer, G. T.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-11-01
- Volume
- 100
- Issue
- 5
- Pages
- 534-540
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W196819375
- Cited by
- 313
- References
- 0
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immunophenotyping of Acute Leukemia by Flow Cytometric Analysis:Use of CD45 and Right-Angle Light Scatter to Gate on Leukemic Blasts in Three-Color Analysis. https://app.cochat.ai/papers/10.1093/ajcp/100.5.534
- The paper
- Borowitz, M. J., Lynn Guenther, K., Shults, K. E., & Stelzer, G. T. (1993). Immunophenotyping of Acute Leukemia by Flow Cytometric Analysis:Use of CD45 and Right-Angle Light Scatter to Gate on Leukemic Blasts in Three-Color Analysis. American Journal of Clinical Pathology. https://doi.org/10.1093/ajcp/100.5.534
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.