Disparate Surgical Margin Lengths of Colorectal Resection Specimens Between In Vivo and In Vitro Measurements: The Effects of Surgical Resection and Formalin Fixation on Organ Shrinkage
The DOI matches its Crossref record.
Abstract
We noticed almost routine disparate results in margin lengths when colorectal specimens are measured in vivo by the surgeon and in vitro by the pathologist. We studied 26 sigmoid and rectum specimens to document the amount of organ shrinkage after surgical removal and fixation. Each specimen had a 5.0-cm segment at each end of the specimen marked by serosal sutures before vascular devitalization. The segments were measured after the specimen sat unfixed for 10 to 20 minutes and after 12 to 18 hours of formalin fixation. The segments shrank to a median length of 3.0 cm (40% of the in vivo length) after 10 to 20 minutes and an additional 0.85 cm, to a median length of 2.15 cm, after fixation. Overall after fixation, the segments shrank 57% of the in vivo length. Approximately 70% of the shrinkage occurred during the first 10 to 20 minutes after removal, and the remaining 30% occurred after fixation. For optimal accuracy, margin distance must be obtained immediately after surgical removal. Once the specimen has been removed for several minutes, the difference between unfixed and fixed margin lengths is 30%. A correction factor of approximately 2x should be applied when interpreting the margin length.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nylund, K., Maconi, G., Hollerweger, A., Ripolles, T., Pallotta, N., Higginson, A., Serra, C., Dietrich, C., Sporea, I., Saftoiu, A., et al. (2017) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0042-115853 · Cited by 163
“Also differences in tissue texture and temperature can cause variability in the tissue impedance thus complicating the comparison between in vivo and in vitro measurements [17, 102].”
BackgroundKimyai-Asadi, A., Goldberg, L. H., & Jih, M. H. (2005) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2005.02.049 · Cited by 100
Metadata
- Authors
- Goldstein, N. S., Soman, A., & Sacksner, J.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-03-01
- Volume
- 111
- Issue
- 3
- Pages
- 349-351
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W1936033711
- Cited by
- 180
- References
- 0
- FWCI
- 0.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.