CoChat

Potential Increased Risk of Ischemic Heart Disease Mortality With Significant Dose Fractionation in the Canadian Fluoroscopy Cohort Study

Open access
Zablotska, L. B., Little, M. P., Cornett, R. J. · 2014 · American Journal of Epidemiology
Cited by 52

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Risks of noncancer causes of death, particularly cardiovascular disease, associated with exposures to high-dose ionizing radiation, are well known. Recent studies have reported excess risk in workers who are occupationally exposed to low doses at a low dose rate, but the risks of moderately fractionated exposures, such as occur during diagnostic radiation procedures, remain unclear. The Canadian Fluoroscopy Cohort Study includes 63,707 tuberculosis patients exposed to multiple fluoroscopic procedures in 1930-1952 and followed-up for death from noncancer causes in 1950-1987. We used a Poisson regression to estimate excess relative risk (ERR) per Gy of cumulative radiation dose to the lung (mean dose = 0.79 Gy; range, 0-11.60). The risk of death from noncancer causes was significantly lower in these subjects compared with the Canadian general population (P < 0.001). We estimated small, nonsignificant increases in the risk of death from noncancer causes with dose. We estimated an ERR/Gy of 0.176 (95% confidence interval: 0.011, 0.393) (n = 5,818 deaths) for ischemic heart disease (IHD) after adjustment for dose fractionation. A significant (P = 0.022) inverse dose fractionation effect in dose trends of IHD was observed, with the highest estimate of ERR/Gy for those with the fewest fluoroscopic procedures per year. Radiation-related risks of IHD decreased significantly with increasing time since first exposure and age at first exposure (both P < 0.05). This is the largest study of patients exposed to moderately fractionated low-to-moderate doses of radiation, and it provides additional evidence of increased radiation-associated risks of death from IHD, in particular, significantly increased radiation risks from doses similar to those from diagnostic radiation procedures. The novel finding of a significant inverse dose-fractionation association in IHD mortality requires further investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/aje/kwt244

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 52

Metadata

Authors
Zablotska, L. B., Little, M. P., & Cornett, R. J.
Venue
American Journal of Epidemiology
Published
2013-10-20
Volume
179
Issue
1
Pages
120-131
ISSN
  • 0002-9262 (ISSN-L)
  • 1476-6256
OpenAlex
W2143327181
Cited by
52
References
4
FWCI
1.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.