The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The Diurnal Blood Pressure Profile: A Population Study
Abstract
This population study included 399 subjects, of whom 370 (93%) showed a significant diurnal blood pressure (BP) rhythm. The nocturnal BP fall was normally distributed and averaged 16 +/- 9 mm Hg systolic and 14 +/- 7 mm Hg diastolic (mean +/- SD). The amplitude of the diurnal BP curve followed a positively skewed distribution, with a mean of 16 +/- 5 mm Hg for systolic BP and 14 +/- 4 mm Hg for diastolic BP. The daily BP maximum occurred at 15:54 +/- 4:47 for systolic BP and at 15:11 +/- 4:20 for diastolic BP. Thirty-four subjects were reexamined after a median interval of 350 days. The test for the presence of a significant diurnal rhythm was discordant in only two subjects. Repeatability (twice the standard deviation of the differences between paired recordings expressed as a percentage of the mean) varied from 11 to 25% for the 24 h, daytime, and overnight BP, and from 76 to 138% for the parameters describing the diurnal BP rhythm. In nine subjects with an initial night/day ratio of mean BP less than 0.78, the nighttime BP was significantly increased at the repeat examination, whereas the opposite tendency was observed in nine subjects with an initial ratio greater than 0.87. In conclusion, the distribution of the nocturnal BP fall is unimodal. The reproducibility of the ambulatory BP is satisfactory for the level of BP and for the presence of a diurnal BP rhythm, but not for the parameters of the diurnal BP curve. Thus, one 24 h recording is insufficient to fully characterize an individual's diurnal BP profile.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
Cited by
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Self-citationGangwisch, J. E., Heymsfield, S. B., Boden-Albala, B., Buijs, R. M., Kreier, F., Pickering, T. G., Rundle, A. G., Zammit, G. K., & Malaspina, D. (2006) · Hypertension · doi:10.1161/01.hyp.0000217362.34748.e0 · Cited by 1,284
Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Self-citationPredictive Role of the Nighttime Blood Pressure
Hansen, T. W., Li, Y., Boggia, J., Thijs, L., Richart, T., & Staessen, J. A. (2011) · Hypertension · doi:10.1161/hypertensionaha.109.133900 · Cited by 597
Self-citationRedon, J., Campos, C., Narciso, M. L., Rodicio, J. L., Pascual, J. M., & Ruilope, L. M. (1998) · Hypertension · doi:10.1161/01.hyp.31.2.712 · Cited by 420
Metadata
- Authors
- Staessen, J., Bulpitt, C. J., O'Brien, E., Cox, J., Fagard, R., Stanton, A., Thijs, L., Hulle, S. V., Vyncke, G., & Amery, A.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-06-01
- Volume
- 5
- Issue
- 6 Pt 1
- Pages
- 386-392
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2327636182
- Cited by
- 168
- References
- 2
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Diurnal Blood Pressure Profile: A Population Study. https://app.cochat.ai/papers/10.1093/ajh/5.6.386
- The paper
- Staessen, J., Bulpitt, C. J., O'Brien, E., Cox, J., Fagard, R., Stanton, A., Thijs, L., Hulle, S. V., Vyncke, G., & Amery, A. (1992). The Diurnal Blood Pressure Profile: A Population Study. American Journal of Hypertension. https://doi.org/10.1093/ajh/5.6.386
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.