Failure-mode and effects analysis in improving a drug distribution system
The DOI matches its Crossref record.
Abstract
The medication error rate in an existing ward stock drug distribution system and in an alternative system developed after failure-mode and effects analysis (FMEA) was applied to the ward stock system was studied. In the ward stock system of a large teaching hospital in Western Australia, bulk drug packs were stored in cupboards on the wards, and drug products were transferred to drug trolleys before dose administration by nurses. A pharmacist used the disguised-observer technique to determine the error rate in the ward stock system for a medical ward and a surgical ward. The errors and each step in the system were studied by FMEA. A unit supply individual-patient dispensing (USIPD) system was formulated to respond to the failure modes identified. In this system, a five-day supply of medication was dispensed for each patient from a satellite pharmacy close to the ward. Medication charts were reviewed by a pharmacist, and drugs were dispensed in labeled vials that were placed in a locked drawer at the patient's bedside. The error rate under the USIPD system was determined. Problem areas in the ward stock system identified by FMEA included drug availability, review of orders, drug selection, patient-related issues, and use of nurses' time. The percentage of opportunities during which any error occurred was significantly lower under the USIPD system on both wards. FMEA was used to identify deficiencies in the ward stock system that led to medication errors in an Australian hospital. An alternative drug distribution system designed to address the problems identified was associated with fewer errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DeRosier, J., Stalhandske, E., Bagian, J. P., & Nudell, T. (2002) · The Joint Commission Journal on Quality Improvement · doi:10.1016/s1070-3241(02)28025-6 · Cited by 611
Keers, R. N., Williams, S. D., Cooke, J., & Ashcroft, D. M. (2013) · Annals of Pharmacotherapy · doi:10.1345/aph.1r147 · Cited by 354
Adverse drug events and medication errors in Australia
Runciman, W. B. (2003) · International Journal for Quality in Health Care · doi:10.1093/intqhc/mzg085 · Cited by 351
Using failure mode and effects analysis to plan implementation of smart i.v. pump technology
Wetterneck, T. B., Skibinski, K. A., Roberts, T. L., Kleppin, S. M., Schroeder, M. E., Enloe, M., Rough, S. S., Hundt, A. S., & Carayon, P. (2006) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp050515 · Cited by 134
Vélez-Díaz-Pallarés, M., Delgado-Silveira, E., Carretero-Accame, M. E., & Bermejo-Vicedo, T. (2013) · BMJ Quality & Safety · doi:10.1136/bmjqs-2012-000983 · Cited by 58
Metadata
- Authors
- McNally, K. M., Page, M. A., & Sunderland, V. B.
- Venue
- American Journal of Health-System Pharmacy
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-01-15
- Volume
- 54
- Issue
- 2
- Pages
- 171-177
- ISSN
- 1079-2082 (ISSN-L)
- 1535-2900
- OpenAlex
- W1881200668
- Cited by
- 86
- References
- 0
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Failure-mode and effects analysis in improving a drug distribution system. https://app.cochat.ai/papers/10.1093/ajhp/54.2.171
- The paper
- McNally, K. M., Page, M. A., & Sunderland, V. B. (1997). Failure-mode and effects analysis in improving a drug distribution system. American Journal of Health-System Pharmacy. https://doi.org/10.1093/ajhp/54.2.171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.