CoChat

AIRBORNE ASBESTOS CONCENTRATIONS IN BUILDINGS

· 1986 · The Annals of Occupational Hygiene
Cited by 34

The DOI matches its Crossref record.

Abstract

Airborne concentrations of asbestos and other fibres were measured in 39 buildings containing asbestos materials used in their construction or present in warm-air heating systems and in four buildings without asbestos materials. Samples were collected onto membrane filters and analysed using both phase contrast optical microscopy (PCM) and transmission electron microscopy (TEM). Of the 235 samples analysed by PCM, 13% gave fibre concentrations above 0.01 fibres per millilitre (f ml −1 ); no sample exceeded 0.075 f ml −1 . However, subsequent TEM analysis showed that most of the fibres were not asbestos and at only one site did the > 5 μm long fibre concentration exceed 0.001 asbestos f ml −1 . All sizes of asbestos fibres were also analysed in the TEM at × 17 000 magnification. Only 20% of the buildings had asbestos fibre concentrations above the limit of quantification (>4 fibres counted) and often only a few chrysotile fibrils were detected. Mass calculations based on the fibre size showed that the average concentration of chrysotile was < 1 ng m −3 at all sites, and only when large amosite fibres were present was the 1 ng m −3 level exceeded.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/annhyg/30.2.185

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 34

Metadata

Venue
The Annals of Occupational Hygiene
Published
1986-04-01
Volume
30
Issue
2
Pages
185-99
ISSN
  • 0003-4878 (ISSN-L)
  • 1475-3162
OpenAlex
W2005892300
Cited by
34
References
0
FWCI
2.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: AIRBORNE ASBESTOS CONCENTRATIONS IN BUILDINGS. https://app.cochat.ai/papers/10.1093/annhyg/30.2.185
The paper
AIRBORNE ASBESTOS CONCENTRATIONS IN BUILDINGS. (1986). The Annals of Occupational Hygiene. https://doi.org/10.1093/annhyg/30.2.185

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.