The DOI matches its Crossref record.
SIZE DISTRIBUTIONS OF CHRYSOTILE ASBESTOS IN A FRICTION PRODUCTS FACTORY AS DETERMINED BY TRANSMISSION ELECTRON MICROSCOPY
Abstract
Airborne chrysotile asbestos size distributions have been measured by transmission electron microscopy from air samples taken in a factory making clutches and brake shoes. The median diameters on samples taken at the three processes were 0.08, 0.13 and 0.13 μm, and the median lengths were 0.86, 1.4 and 1.5 μm. Median aspect ratios were close to 10. A few per cent of fibres were longer than 5 μm, and between a fifth and a half of these would be counted by a phase-contrast optical microscope resolving 0.3 μjm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In these studies the non-regulated fibers, SAF, and LAF with a diameter < 0.2 μm, represented between 50 and 100% of the total fibers, with the majority of samples between 80 and 100% respectively.”
From Quantification of short and long asbestos fibers to assess asbestos exposure: A review of fiber size toxicity (2014) · cites this paper as [17]
In the citing paper
“Analysis of asbestos size categories according to sectors of activity and the concentration levels found in the literature [10-18] highlight a number of sectors with higher prevalence of SAF, including in particular asbestos cement production, friction materials production, brake systems repair and mining.”
From Quantification of short and long asbestos fibers to assess asbestos exposure: A review of fiber size toxicity (2014) · cites this paper as [17]
Citations
Cited by
Sorted by citations
Boulanger, G., Andujar, P., Pairon, J.-C., Billon-Galland, M.-A., Dion, C., Dumortier, P., Brochard, P., Sobaszek, A., Bartsch, P., Paris, C., et al. (2014) · Environmental Health · doi:10.1186/1476-069x-13-59 · Cited by 176
Metadata
- Venue
- The Annals of Occupational Hygiene
- Publisher
- Oxford University Press (OUP)
- Published
- 1989-11-01
- ISSN
- 1475-3162
- Cited by
- 6
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SIZE DISTRIBUTIONS OF CHRYSOTILE ASBESTOS IN A FRICTION PRODUCTS FACTORY AS DETERMINED BY TRANSMISSION ELECTRON MICROSCOPY. https://app.cochat.ai/papers/10.1093/annhyg/33.4.583
- The paper
- SIZE DISTRIBUTIONS OF CHRYSOTILE ASBESTOS IN A FRICTION PRODUCTS FACTORY AS DETERMINED BY TRANSMISSION ELECTRON MICROSCOPY. (1989). The Annals of Occupational Hygiene. https://doi.org/10.1093/annhyg/33.4.583