CoChat

Multicenter harmonization study for PD-L1 IHC testing in non-small-cell lung cancer

Open access
Adam, J., Le Stang, N., Rouquette, I., Cazes, A., Badoual, C., Pinot-Roussel, H., Tixier, L., Danel, C., Damiola, F., Damotte, D., Penault-Llorca, F., Lantuéjoul, S. · 2018 · Annals of Oncology
Cited by 215

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Background: Various programed death ligand 1 (PD-L1) immunohistochemistry (IHC) assays have been developed and used in clinical trials in association with different drugs. In order to harmonize and make PD-L1 testing in non-small-cell lung cancer (NSCLC) widely available, we conducted a multicenter study comparing PD-L1 standardized assays and laboratory-developed tests (LDTs). Methods: IHC with five anti-PD-L1 monoclonal antibodies (28-8, 22C3, E1L3N, SP142 and SP263) was performed concomitantly on 41 NSCLC surgical specimens in 7 centers using Dako Autostainer Link 48 (3 centers), Leica Bond (2 centers) or Ventana BenchMark Ultra (2 centers) platforms. For each matching platform, 22C3, 28-8 and SP263 assays were performed. For nonmatching platforms and other antibodies, LDTs were developed in each center. A total of 35 stainings were performed for each case across different platforms and antibodies. PD-L1 staining was assessed in tumor cells and immune cells by seven trained thoracic pathologists. For statistical analysis, 1%, 50% and 1%, 5%, 10% expression thresholds were used for tumor cells and immune cells, respectively. Results: 28-8, 22C3 and SP263 assays were highly concordant for tumor cells staining across the five Dako or Ventana platforms. Among 27 LDTs developed in 7 centers on Dako, Ventana and Leica platforms, 14 (51.8%) demonstrated similar concordance when compared with reference assays for tumor cell staining. Clone SP263 achieved the highest concordance rate across all platforms. Lower concordance was observed for immune cells staining when using a four categories scale. Conclusion: 28-8, 22C3 and SP263 assays had close analytical performance for tumor cell staining across seven centers. Some LDTs on Dako, Ventana and Leica platforms achieved similar concordance, but caution is warranted for their validation. These LDTs will be further validated in order to provide recommendations for the use of assays and LDT for PD-L1 testing in NSCLC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/annonc/mdy014

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Adam, J., Le Stang, N., Rouquette, I., Cazes, A., Badoual, C., Pinot-Roussel, H., Tixier, L., Danel, C., Damiola, F., Damotte, D., Penault-Llorca, F., & Lantuéjoul, S.
Venue
Annals of Oncology
Publisher
Elsevier BV
Published
2018-04
Volume
29
Issue
4
Pages
953-958
ISSN
0923-7534 (ISSN-L)
OpenAlex
W2786665544
Cited by
215
References
17
FWCI
12.47
Type
journal article
Language
en
Open access
hybrid
Licence
Funders
  • Bristol-Myers Squibb
  • Merck Sharp and Dohme
  • AstraZeneca
  • Roche

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.