The Effect on Fit of Multiple Consecutive Donning and Doffing of N95 Filtering Facepiece Respirators

Vuma, Cynthia Danisile, Manganyi, Jeanneth, Wilson, Kerry, Rees, David · 2019 · Annals of Work Exposures and Health
Cited by 56

The DOI matches its Crossref record.

Abstract

Background: N95 filtering facepiece respirators (FFRs) are widely used in healthcare to reduce transmission of airborne infectious diseases. These respirators are generally described as single use or limited reuse devices, but cost and operational issues mean that they may be donned and doffed multiple times. There is scant research on the effect of this practice on adequacy of fit. Objective: The purpose of this study was to measure the effect on respirator fit of multiple donning and doffing of N95 FFRs. Methods: This was an experiment in which 16 women and 9 men employed by the National Institute for Occupational Health (NIOH), Johannesburg, donned their same N95 FFR six times. All 25 were trained in the correct wearing of the devices before the experiment. Four models of respirators were used: the six who did not use respirators at work (novice subjects) were issued a 3M 1860 FFR and the others used their currently supplied one. During the experiment subjects donned their respirators under the supervision of the tester. Quantitative fit testing was done in the NIOH Occupational Hygiene laboratory after each donning according to the OSHA-Accepted Fit Test Protocol using the TSI PortaCount Pro+ Model 8038 Respirator Fit Tester. During the test, fit was measured after each of seven exercises and then an overall fit factor was computed. Only individuals who achieved an initial overall fit factor of ≥100 were allowed to continue participation in the study. Median overall fit factors were calculated for the 25 subjects for each donning and changes across them was examined using Wilcoxon rank sum tests. Men and women and frequent and infrequent users were compared across the six tests. Infrequent use was defined as subjects who wore respirators ≤ once per week, and novice subjects. Results: Two subjects (8%) had an overall fit factor <100 at fit Test 2, 6 (24%) at Test 3, and 8 (32%) at Tests 4, 5, and 6. Thirteen respirator users (52%) achieved ≥100 throughout the fit testing, so 12 had at least one failure at either Tests 2–6. Five of the 12 subjects with at least one failure showed persistent failures on all subsequent donnings. Six subjects out of 12 (50%) who failed a fit test achieved an overall fit factor >100 at a subsequent test. There was a significant difference between the median first and sixth overall fit factors (195 versus 150; P = 0.0271), but not between the second and sixth (161 versus 150; P = 0.3584). Men and women had similar overall fit factors, but infrequent users had larger average overall fit factors than frequent users after all six donnings. Conclusion: Forty-eight percent of study subjects failed at least one fit test after re-donning an N95 FFR. The fit test data suggest that donning practices probably accounted for the fit test failures. The 50% of subjects who produced overall fit factors ≥100 after a test of <100 supports this contention.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/annweh/wxz060

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 56

Metadata

Authors
Vuma, C. D., Manganyi, J., Wilson, K., & Rees, D.
Venue
Annals of Work Exposures and Health
Published
2019-08-27
Volume
63
Issue
8
Pages
930-936
ISSN
  • 2398-7308 (ISSN-L)
  • 2398-7316
OpenAlex
W2970278668
Cited by
56
References
0
FWCI
6.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Effect on Fit of Multiple Consecutive Donning and Doffing of N95 Filtering Facepiece Respirators. https://app.cochat.ai/papers/10.1093/annweh/wxz060
The paper
Vuma, C. D., Manganyi, J., Wilson, K., & Rees, D. (2019). The Effect on Fit of Multiple Consecutive Donning and Doffing of N95 Filtering Facepiece Respirators. Annals of Work Exposures and Health. https://doi.org/10.1093/annweh/wxz060

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.