Using video-oriented instructions to speed up sequence comparison
Open accessThe DOI matches its Crossref record.
Abstract
MOTIVATION: This document presents an implementation of the well-known Smith-Waterman algorithm for comparison of proteic and nucleic sequences, using specialized video instructions. These instructions, SIMD-like in their design, make possible parallelization of the algorithm at the instruction level. RESULTS: Benchmarks on an ULTRA SPARC running at 167 MHz show a speed-up factor of two compared to the same algorithm implemented with integer instructions on the same machine. Performance reaches over 18 million matrix cells per second on a single processor, giving to our knowledge the fastest implementation of the Smith-Waterman algorithm on a workstation. The accelerated procedure was introduced in LASSAP--a LArge Scale Sequence compArison Package software developed at INRIA--which handles parallelism at higher level. On a SUN Enterprise 6000 server with 12 processors, a speed of nearly 200 million matrix cells per second has been obtained. A sequence of length 300 amino acids is scanned against SWISSPROT R33 (1,8531,385 residues) in 29 s. This procedure is not restricted to databank scanning. It applies to all cases handled by LASSAP (intra- and inter-bank comparisons, Z-score computation, etc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accelerated Profile HMM Searches
Eddy, S. R. (2011) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002195 · Cited by 6,975
“Several vector methods have been described for accelerating classical Smith/Waterman local sequence alignment [34,35], and methods for accelerating Smith/Waterman dynamic programming (DP) recursions are readily adapted to profile HMMs.”
MethodHH-suite3 for fast remote homology detection and deep protein annotation
Steinegger, M., Meier, M., Mirdita, M., Vöhringer, H., Haunsberger, S. J., & Söding, J. (2019) · BMC Bioinformatics · doi:10.1186/s12859-019-3019-7 · Cited by 1,145
SHRiMP: Accurate Mapping of Short Color-space Reads
Rumble, S. M., Lacroute, P., Dalca, A. V., Fiume, M., Sidow, A., & Brudno, M. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000386 · Cited by 575
GMAP and GSNAP for Genomic Sequence Alignment: Enhancements to Speed, Accuracy, and Functionality
Wu, T. D., Reeder, J., Lawrence, M., Becker, G., & Brauer, M. J. (2016) · Methods in Molecular Biology · doi:10.1007/978-1-4939-3578-9_15 · Cited by 431
Striped Smith–Waterman speeds database searches six times over other SIMD implementations
Farrar, M. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btl582 · Cited by 415
Metadata
- Authors
- Wozniak, A.
- Venue
- Bioinformatics
- Publisher
- Oxford University Press (OUP)
- Published
- 1997
- Volume
- 13
- Issue
- 2
- Pages
- 145-150
- ISSN
- 0266-7061 (ISSN-L)
- 1367-4803
- 1460-2059
- OpenAlex
- W2133098231
- Cited by
- 141
- References
- 0
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using video-oriented instructions to speed up sequence comparison. https://app.cochat.ai/papers/10.1093/bioinformatics/13.2.145
- The paper
- Wozniak, A. (1997). Using video-oriented instructions to speed up sequence comparison. Bioinformatics. https://doi.org/10.1093/bioinformatics/13.2.145
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.