QAcon: single model quality assessment using protein structural and contact information with machine learning techniques
Open accessThe DOI matches its Crossref record.
Abstract
Motivation: Protein model quality assessment (QA) plays a very important role in protein structure prediction. It can be divided into two groups of methods: single model and consensus QA method. The consensus QA methods may fail when there is a large portion of low quality models in the model pool. Results: In this paper, we develop a novel single-model quality assessment method QAcon utilizing structural features, physicochemical properties, and residue contact predictions. We apply residue-residue contact information predicted by two protein contact prediction methods PSICOV and DNcon to generate a new score as feature for quality assessment. This novel feature and other 11 features are used as input to train a two-layer neural network on CASP9 datasets to predict the quality of a single protein model. We blindly benchmarked our method QAcon on CASP11 dataset as the MULTICOM-CLUSTER server. Based on the evaluation, our method is ranked as one of the top single model QA methods. The good performance of the features based on contact prediction illustrates the value of using contact information in protein quality assessment. Availability and Implementation: The web server and the source code of QAcon are freely available at: http://cactus.rnet.missouri.edu/QAcon Supplementary information: Supplementary data are available at Bioinformatics online.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deep learning methods in protein structure prediction
Torrisi, M., Pollastri, G., & Le, Q. (2020) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2019.12.011 · Cited by 284
MLACP: machine-learning-based prediction of anticancer peptides
Manavalan, B., Basith, S., Shin, T. H., Choi, S., Kim, M. O., & Lee, G. (2017) · Oncotarget · doi:10.18632/oncotarget.20365 · Cited by 275
Manavalan, B., Basith, S., Shin, T. H., Wei, L., & Lee, G. (2019) · Molecular Therapy - Nucleic Acids · doi:10.1016/j.omtn.2019.04.019 · Cited by 219
Cao, R., Freitas, C., Chan, L., Sun, M., Jiang, H., & Chen, Z. (2017) · Molecules · doi:10.3390/molecules22101732 · Cited by 203
Self-citationPredicting protein structural classes for low-similarity sequences by evaluating different features
Zhu, X.-J., Feng, C.-Q., Lai, H.-Y., Chen, W., & Hao, L. (2019) · Knowledge-Based Systems · doi:10.1016/j.knosys.2018.10.007 · Cited by 195
Metadata
- Authors
- Cao, R., Adhikari, B., Bhattacharya, D., Sun, M., Hou, J., & Cheng, J.
- Venue
- Bioinformatics
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-11-29
- Volume
- 33
- Issue
- 4
- Pages
- 586-588
- ISSN
- 1367-4803 (ISSN-L)
- 1367-4811
- OpenAlex
- W2565608178
- Cited by
- 94
- References
- 0
- FWCI
- 8.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: QAcon: single model quality assessment using protein structural and contact information with machine learning techniques. https://app.cochat.ai/papers/10.1093/bioinformatics/btw694
- The paper
- Cao, R., Adhikari, B., Bhattacharya, D., Sun, M., Hou, J., & Cheng, J. (2017). QAcon: single model quality assessment using protein structural and contact information with machine learning techniques. Bioinformatics. https://doi.org/10.1093/bioinformatics/btw694
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.