The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
THE CIRCLE SYSTEM AS A HUMIDIFIER
Open accessAbstract
In a laboratory model, humidity output was investigated in relation to the design of a circle absorber system. A 70-kg subject was simulated with fresh gas flows of 0.5, 2 or 5 litre min-1. Different circle systems, absorption canisters and tubings were studied. It was found that both the type of circle system (according to Eger's classification) and the size of the absorption canister, influenced the humidity of inspired gases. Coaxial tubing only moderately increased the humidity. If a fresh gas flow of 0.5 liter min-1 was used, optimum moisture contents were attained, irrespective of the circle system tested. Low fresh gas flows, a small canister and an Eger A type circle system, were factors which increased humidification.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Anesthesia with an FGF ≤ 1 L·min-1 does not only effectively maintain intraoperative conditioning (i.e., heating and moisturizing) of inspired gases55 but also saves inhalational anesthetics.”
From A call for immediate climate action in anesthesiology: routine use of minimal or metabolic fresh gas flow reduces our ecological footprint (2023) · cites this paper as [55]
Citations
Cites
Studies on the conditioning of air in the respiratory tract.
Ingelstedt, S. (1956) · PubMed · Cited by 234
Déry, R., Pelletier, J., Jacques, A., Clavet, M., & Houde, J. (1967) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03003698 · Cited by 116
Humidity and Temperature Changes during Low Flow and Closed System Anaesthesia
Aldrete, J. A., Cubillos, P., & Sherrill, D. (1981) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1981.tb01657.x · Cited by 50
Bengtson, J. P., Sonander, H., & Stenqvist, O. (1987) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1987.tb02534.x · Cited by 42
Self-citationHumidification of the Circle Absorber System
Chalon, J., Patel, C. B., Ramanathan, S., & Turndorf, H. (1978) · Anesthesiology · doi:10.1097/00000542-197802000-00011 · Cited by 17
A Method of Quantitating Humidity in the Anesthesia Circuit by Temperature Control
Weeks, D. B., & BROMAN, K. E. (1970) · Anesthesia & Analgesia · doi:10.1213/00000539-197003000-00022 · Cited by 9
Cited by
Rübsam, M.-L., Kruse, P., Dietzler, Y., Kropf, M., Bette, B., Zarbock, A., Kim, S.-C., & Hönemann, C. (2023) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-022-02393-z · Cited by 39
Metadata
- Authors
- BENGTSON, J. P., BENGTSON, A., & STENQVIST, O.
- Affiliations
- Sahlgrenska University Hospital (SE)
- ORCID
- STENQVIST, O.
- Venue
- British Journal of Anaesthesia
- Publisher
- Elsevier BV
- Published
- 1989-10
- Volume
- 63
- Issue
- 4
- Pages
- 453-457
- ISSN
- 0007-0912 (ISSN-L)
- OpenAlex
- W1965869431
- Cited by
- 30
- References
- 6
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2018: 1 · 2016: 1 · 2014: 1 · 2013: 1 · 2012: 2
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (vor, 10291 d)
- Locations
- British Journal of Anaesthesia (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Biomedical and Chemical Research
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
- Keywords
- circle system, humidification, anesthesia breathing circuit, fresh gas flow, moisture content
- MeSH terms
- Absorption, Anesthesia, Closed-Circuit, Anesthesia, Inhalation, Evaluation Studies as Topic, Humans, Humidity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.