CoChat

Effect of propofol anaesthesia on the event-related potential mismatch negativity and the auditory-evoked potential N1

Open access
Simpson, T.P., Manara, A.R., Kane, N.M., Barton, R.L., Rowlands, C.A., Butler, S.R. · 2002 · British Journal of Anaesthesia
Cited by 58

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Studies on the effects of anaesthesia on event-related potentials and long latency auditory-evoked potentials (AEP) are sparse. Both provide information on cortical processing and may have potential as monitors of awareness. We studied the effect of propofol on the event-related potential mismatch negativity (MMN) and the long-latency AEP NI. METHODS: Twenty-one patients received 1 microgram ml-1 stepped increases in the target concentration of propofol using Diprifusor until a maximum of 6 micrograms ml-1 was achieved or the patient had lost consciousness. Neurophysiological responses (MMN and N1) and the patients' level of consciousness were recorded before the administration of propofol and at a target effector site concentration of propofol of 1, 2, 3, 4, and 6 micrograms ml-1. Grand average evoked potentials were computed at baseline, before the administration of propofol (A); at the highest propofol concentration at which each patient was responsive (B); and at the concentration of propofol at which the patient became unconscious (C). RESULTS: Patients lost consciousness at different target concentrations of propofol, all being unresponsive by 4 micrograms ml-1. The response to the deviant stimuli used to elicit duration-shift MMN was significantly more negative than to the standard stimuli at A (mean difference 2.58 microV, P = 0.0011) but this difference was virtually abolished at point B, before the patients lost consciousness (mean difference 0.63 microV, P = ns). The amplitude of N1 evoked by standard stimuli was negative compared with electrical baseline at both point A (mean amplitude -3.81 microV, P < 0.001) and at point B (mean amplitude -2.2 microV, P = 0.002), but was no longer significantly different to baseline at point C (mean amplitude 0.51 microV, P = ns). The change in the mean amplitude of N1 from last awake (point B) to first unconscious (point C) was also significant (mean difference in amplitude 1.69 microV, P = 0.02). CONCLUSIONS: MMN is unlikely to be a clinically useful tool to detect awareness in surgical patients. In contrast, the loss of N1 may identify the transition from consciousness to unconsciousness and deserves further study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/bja/89.3.382

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 58

Metadata

Authors
Simpson, T. P., Manara, A. R., Kane, N. M., Barton, R. L., Rowlands, C. A., & Butler, S. R.
Venue
British Journal of Anaesthesia
Publisher
Elsevier BV
Published
2002-09
Volume
89
Issue
3
Pages
382-388
ISSN
0007-0912 (ISSN-L)
OpenAlex
W2110977832
Cited by
58
References
1
FWCI
3.43
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.