CoChat

Risk factors for anaesthetic-related death in cats: results from the confidential enquiry into perioperative small animal fatalities (CEPSAF) †

Open access
Brodbelt, D.C., Pfeiffer, D.U., Young, L.E., Wood, J.L.N. · 2007 · British Journal of Anaesthesia
Cited by 222

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Cats are commonly anaesthetized in veterinary practice, but recent figures describing the frequency of or risk factors for anaesthetic-related death are not available. The aims of this study were to address these deficiencies. METHODS: A nested case-control study was undertaken in 117 UK veterinary centres. All anaesthetic and sedation procedures and anaesthetic and sedation-related deaths (i.e. 'cases') occurring within 48 h were recorded. Details of patient, procedure, and perioperative management were recorded for all cases and randomly selected non-deaths (controls). A detailed statistical model of factors associated with anaesthetic and sedation-related death was constructed. RESULTS: Between June 2002 and June 2004, 175 deaths were classified as anaesthetic and sedation-related and 14 additional deaths (with insufficient information to be excluded) were included for the estimation of risk. During the study, 79 178 anaesthetic and sedation procedures were recorded and the overall risk of anaesthetic and sedation-related death was 0.24% (95% CI 0.20-0.27). Factors associated with increased odds of anaesthetic-related death were poor health status (ASA physical status classification), increasing age, extremes of weight, increasing procedural urgency and complexity, endotracheal intubation, and fluid therapy. Pulse monitoring and pulse oximetry were associated with reduced odds. CONCLUSIONS: The risk of anaesthetic-related death in cats appears to have decreased since the last published study in the UK. The results should aid the preoperative identification of cats at greatest risk. Greater care with endotracheal intubation and fluid administration are recommended, and pulse and pulse oximetry monitoring should be routinely implemented in cats.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/bja/aem229

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 222

Metadata

Authors
Brodbelt, D. C., Pfeiffer, D. U., Young, L. E., & Wood, J. L. N.
Venue
British Journal of Anaesthesia
Publisher
Elsevier BV
Published
2007-11
Volume
99
Issue
5
Pages
617-623
ISSN
0007-0912 (ISSN-L)
OpenAlex
W2136949000
Cited by
222
References
3
FWCI
6.88
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Risk factors for anaesthetic-related death in cats: results from the confidential enquiry into perioperative small animal fatalities (CEPSAF) †. https://app.cochat.ai/papers/10.1093/bja/aem229
The paper
Brodbelt, D. C., Pfeiffer, D. U., Young, L. E., & Wood, J. L. N. (2007). Risk factors for anaesthetic-related death in cats: results from the confidential enquiry into perioperative small animal fatalities (CEPSAF) †. British Journal of Anaesthesia. https://doi.org/10.1093/bja/aem229

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.