Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 1

The DOI matches its Crossref record.

Comparison of percutaneous antegrade double-J ureteral stent placement: first-hand vs. nephrostomy route approaches

Arslan, Muhammet, Aslan, Halil S, Alver, Kadir H, Demirci, Mahmut · 2024 · British Journal of Radiology

Abstract

Objective: This study aimed to conduct a comparative analysis of procedural efficacy, safety, and patient outcomes between 2 distinct approaches for percutaneous antegrade double-J ureteral stent (DJS) insertion: the first-hand approach and via a nephrostomy route. Methods: Electronic records of patients undergoing percutaneous antegrade ureteral DJS placement from January 2016 to 2023 were reviewed. Patients were categorized into 2 groups based on stent placement technique: the first-hand group, involving a single-stage approach without prior percutaneous nephrostomy catheter insertion, and the nephrostomy group, where stent placement occurred through a percutaneous nephrostomy tube. Clinical data, including patient demographics, primary diagnoses, procedural details, complication rates, stent placement success, and post-procedural outcomes, were collected and analysed. Results: Both approaches demonstrated high technical success rates (93.1%). However, the nephrostomy route group exhibited a comparatively higher fluoroscopy exposure rate (8.2 min) than the first-hand group (6.8 min). Moreover, the complication risk increased by 3.08 times in patients treated with the nephrostomy method (P = .047). Notably, in cases of urinary malignancies, the preference was for placing DJS via nephrostomy. Conclusion: The first-hand approach should be prioritized as the initial choice in suitable cases owing to its reduced fluoroscopy time, lower complication rate, and the single-stage nature of the procedure. Advances in knowledge: With the exception of cases necessitating urgent drainage, such as post-renal acute renal failure and urosepsis, the first-hand method is the primary approach for inserting DJS. This is primarily due to the significantly shorter radiation time and the single-stage nature of the procedure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/bjr/tqae143

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 13

  1. van der Meer, 2017, Antegrade ureteral stenting is a good alternative for the retrograde approach, Curr Urol, 10, 87, 10.1159/000447157 · doi:10.1159/000447157
  2. Bahu, 2013, Nephrostomy tube related pyelonephritis in patients with cancer: epidemiology, infection rate and risk factors, J Urol, 189, 130, 10.1016/j.juro.2012.08.094 · DOI
  3. Tlili, 2021, Antegrade double-J stent placement for the treatment of malignant obstructive uropathy: a retrospective cohort study, Ann Med Surg (Lond), 69, 102726
  4. Hausegger, 2006, Percutaneous nephrostomy and antegrade ureteral stenting: technique—indications—complications, Eur Radiol, 16, 2016, 10.1007/s00330-005-0136-7 · doi:10.1007/s00330-005-0136-7
  5. Tibana, 2019, Percutaneous nephrostomy versus antegrade double-J stent placement in the treatment of malignant obstructive uropathy: a cost-effectiveness analysis from the perspective of the Brazilian public health care system, Radiol Bras, 52, 305, 10.1590/0100-3984.2018.0127 · doi:10.1590/0100-3984.2018.0127
  6. Ordek, 2022, Antegrade placement of JJ catheter in the treatment of malignant ureteral obstruction: retrospective analysis of a single centre, Arch Ital Urol Androl, 94, 91, 10.4081/aiua.2022.1.91 · doi:10.4081/aiua.2022.1.91
  7. Harding, 1993, Percutaneous antegrade ureteric stent insertion in malignant disease, J R Soc Med, 86, 511
  8. Kahriman, 2019, Percutaneous antegrade ureteral stent placement: single center experience, Diagn Interv Radiol, 25, 127, 10.5152/dir.2019.18252 · doi:10.5152/dir.2019.18252
  9. Chitale, 2010, One-stage tubeless antegrade ureteric stenting: a safe and cost-effective option?, Annals, 92, 218, 10.1308/003588410X12518836439128 · doi:10.1308/003588410x12518836439128
  10. Ganatra, 2005, The management of malignant ureteral obstruction treated with ureteral stents, J Urol, 174, 2125, 10.1097/01.ju.0000181807.56114.b7 · doi:10.1097/01.ju.0000181807.56114.b7
  11. Dyer, 2002, Complications of ureteral stent placement, Radiographics, 22, 1005, 10.1148/radiographics.22.5.g02se081005 · DOI · Paper page
  12. Rao, 2011, Extra-anatomical complications of antegrade double-J insertion, Indian J Urol, 27, 19, 10.4103/0970-1591.78408 · doi:10.4103/0970-1591.78408
  13. Hsu, 2016, Use of percutaneous nephrostomy and ureteral stenting in management of ureteral obstruction, World J Nephrol, 5, 172, 10.5527/wjn.v5.i2.172 · doi:10.5527/wjn.v5.i2.172

Metadata

Authors
Arslan, M., Aslan, H. S., Alver, K. H., & Demirci, M.
Affiliations
  • Department of Radiology, Pamukkale University Faculty of Medicine , Denizli, 20070, Turkey
  • Department of Radiology, Denizli State Hospital , Denizli, 20040, Turkey
Venue
British Journal of Radiology
Published
2024-08-09
Volume
97
Issue
1162
Pages
1683-1689
ISSN
  • 0007-1285
  • 1748-880X
Cited by
1
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of percutaneous antegrade double-J ureteral stent placement: first-hand vs. nephrostomy route approaches. https://app.cochat.ai/papers/10.1093/bjr/tqae143
The paper
Arslan, M., Aslan, H. S., Alver, K. H., & Demirci, M. (2024). Comparison of percutaneous antegrade double-J ureteral stent placement: first-hand vs. nephrostomy route approaches. British Journal of Radiology. https://doi.org/10.1093/bjr/tqae143

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.