The DOI matches its Crossref record.
A clinical study of motor evoked potentials using a triple stimulation technique
Open accessAbstract
Amplitudes of motor evoked potentials (MEPs) are usually much smaller than those of motor responses to maximal peripheral nerve stimulation, and show marked variation between normal subjects and from one stimulus to another. Consequently, amplitude measurements have low sensitivity to detect central motor conduction failures due to the broad range of normal values. Since these characteristics are mostly due to varying desynchronization of the descending action potentials, causing different degrees of phase cancellation, we applied the recently developed triple stimulation technique (TST) to study corticospinal conduction to 489 abductor digiti minimi muscles of 271 unselected patients referred for possible corticospinal dysfunction. The TST allows resynchronization of the MEP, and thereby a quantification of the proportion of motor units activated by the transcranial stimulus. TST results were compared with those of conventional MEPs. In 212 of 489 sides, abnormal TST responses suggested conduction failure of various degrees. By contrast, conventional MEPs detected conduction failures in only 77 of 489 sides. The TST was therefore 2.75 times more sensitive than conventional MEPs in disclosing corticospinal conduction failures. When the results of the TST and conventional MEPs were combined, 225 sides were abnormal: 145 sides showed central conduction failure, 13 sides central conduction slowing and 67 sides both conduction failure and slowing. It is concluded that the TST is a valuable addition to the study of MEPs, since it improves detection and gives quantitative information on central conduction failure, an abnormality which appears to be much more frequent than conduction slowing. This new technique will be useful in following the natural course and the benefit of treatments in disorders affecting central motor conduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
Rossini, P. M., Burke, D., Chen, R., Cohen, L. G., Daskalakis, Z., Di Iorio, R., Di Lazzaro, V., Ferreri, F., Fitzgerald, P. B., George, M. S., et al. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.02.001 · Cited by 2,753
Transcranial magnetic stimulation in neurology
Kobayashi, M., & Pascual-Leone, A. (2003) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00321-1 · Cited by 1,297
A practical guide to diagnostic transcranial magnetic stimulation: Report of an IFCN committee
Groppa, S., Oliviero, A., Eisen, A., Quartarone, A., Cohen, L. G., Mall, V., Kaelin-Lang, A., Mima, T., Rossi, S., Thickbroom, G. W., et al. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.01.010 · Cited by 1,274
Electrodiagnostic criteria for diagnosis of ALS
de Carvalho, M., Dengler, R., Eisen, A., England, J. D., Kaji, R., Kimura, J., Mills, K., Mitsumoto, H., Nodera, H., Shefner, J., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.143 · Cited by 1,194
Metadata
- Authors
- Magistris, M. R., Rösler, K. M., Truffert, A., Landis, T., & Hess, C. W.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-02
- Volume
- 122
- Issue
- 2
- Pages
- 265-279
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2073112864
- Cited by
- 211
- References
- 0
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A clinical study of motor evoked potentials using a triple stimulation technique. https://app.cochat.ai/papers/10.1093/brain/122.2.265
- The paper
- Magistris, M. R., Rösler, K. M., Truffert, A., Landis, T., & Hess, C. W. (1999). A clinical study of motor evoked potentials using a triple stimulation technique. Brain. https://doi.org/10.1093/brain/122.2.265
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.