The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Liquid chromatography-electrospray ionization-mass spectrometry: the future of DNA adduct detection
Abstract
Over the past 40 years considerable emphasis has been placed on the development of accurate and sensitive methods for the detection and quantitation of DNA adducts. The formation of DNA adducts resulting from the covalent interaction of genotoxic carcinogens with DNA, derived from exogenous and endogenous sources, either directly or following metabolic activation, can if not repaired lead to mutations in critical genes such as those involved in the regulation of cellular growth and subsequent development of cancer. The major analytical challenge has been to detect levels of DNA adducts at the level of 0.1-1 adducts per 10(8) unmodified DNA bases using only low microgram amounts of DNA, and with high specificity and accuracy, in humans exposed to genotoxic carcinogens derived from occupational, environmental, dietary and life-style sources. In this review we will highlight the merits as well as discuss the progress made by liquid chromatography coupled to electrospray ionization mass spectrometry as a method for DNA adduct detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferential Formation of Benzo[ a ]pyrene Adducts at Lung Cancer Mutational Hotspots in P53
Denissenko, M. F., Pao, A., Tang, M.-S., & Pfeifer, G. P. (1996) · Science · doi:10.1126/science.274.5286.430 · Cited by 1,650
Frelon, S., Douki, T., Ravanat, J.-L., Pouget, J.-P., Tornabene, C., & Cadet, J. (2000) · Chemical Research in Toxicology · doi:10.1021/tx000085h · Cited by 271
Cited by
Bartsch, H., & Nair, J. (2006) · Langenbeck's Archives of Surgery · doi:10.1007/s00423-006-0073-1 · Cited by 516
Swenberg, J. A., Lu, K., Moeller, B. C., Gao, L., Upton, P. B., Nakamura, J., & Starr, T. B. (2011) · Toxicological Sciences · doi:10.1093/toxsci/kfq371 · Cited by 377
Turesky, R. J., & Le Marchand, L. (2011) · Chemical Research in Toxicology · doi:10.1021/tx200135s · Cited by 337
Advances in Chemical Carcinogenesis: A Historical Review and Prospective
Loeb, L. A., & Harris, C. C. (2008) · Cancer Research · doi:10.1158/0008-5472.can-08-2852 · Cited by 317
Progress and Challenges in Selected Areas of Tobacco Carcinogenesis
Hecht, S. S. (2008) · Chemical Research in Toxicology · doi:10.1021/tx7002068 · Cited by 282
Metadata
- Authors
- Singh, R., & Farmer, P. B.
- Venue
- Carcinogenesis
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-11-04
- Volume
- 27
- Issue
- 2
- Pages
- 178-196
- ISSN
- 0143-3334 (ISSN-L)
- 1460-2180
- OpenAlex
- W2105499761
- Cited by
- 221
- References
- 2
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid chromatography-electrospray ionization-mass spectrometry: the future of DNA adduct detection. https://app.cochat.ai/papers/10.1093/carcin/bgi260
- The paper
- Singh, R., & Farmer, P. B. (2006). Liquid chromatography-electrospray ionization-mass spectrometry: the future of DNA adduct detection. Carcinogenesis. https://doi.org/10.1093/carcin/bgi260
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.