A case study of digital-twin-modelling analysis on power-plant-performance optimizations
The DOI matches its Crossref record.
Abstract
China Energy’s National Institute of Clean-and-Low-Carbon Energy (NICE) is developing a Power Plant Smart Management (PPSM) platform that employs digital-twin technology to undertake techno-economic modelling analysis on China Energy’s existing coal-fired power-plant units and explore cost-effective solutions to improve those plant units’ thermal efficiencies and operating performance. This paper presents a case study of PPSM on a 320-MWe coal-fired thermal power-plant unit, demonstrating how the digital-twin technology was employed to explore and analyse optimization solutions. Various optimization solutions and their cost-effectiveness were assessed using the digital-twin-modelling analysis; the results indicated the optimization solutions are expected to improve the plant unit’s operating efficiency and reduce its current electricity-generation coal consumption by up to 3.5 g/kWh standard coal equivalent (sce), worth annual fuel-cost savings of approximately 4 million RMB for a single unit or 8 million RMB for the two identical 320-MWe units that the power plant currently operates. The digital twin was also employed to assess the power-plant unit’s operating economics during both summer and winter. In summer, when the unit operates in electricity-generation-only mode, the unit’s operating thermal efficiency could drop by up to 6% points following the grid demand of load changes from 100% maximum continuous rating (MCR) down to 30%MCR, resulting in an ~ 45 RMB/MWh increase of electricity-generation cost. In winter, when the unit operates in combined heat and power (CHP) cogeneration mode, for the same boiler load, the CHP operation increases the plant unit’s operating profit with increasing district-heating duty, although the relative profit gain from the CHP cogeneration could start to decrease when the district-heating steam-extraction flow increases to a certain point that varies depending on the market prices of heat and electricity, while the fuel cost was found to be equivalent to ~50% of the unit’s total CHP income cogenerated from its electricity and district heat outputs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“CHP”
From Digital twin in energy industry: Proposed robust digital twin for power plant and other complex capital-intensive large engineering systems (2022) · cites this paper as Xu et al. (2019)
In the citing paper
“Simulating the”
From Digital twin in energy industry: Proposed robust digital twin for power plant and other complex capital-intensive large engineering systems (2022) · cites this paper as Xu et al. (2019)
In the citing paper
“Irregular load changes,”
From Digital twin in energy industry: Proposed robust digital twin for power plant and other complex capital-intensive large engineering systems (2022) · cites this paper as Xu et al. (2019)
In the citing paper
“Using real operating data”
From Digital twin in energy industry: Proposed robust digital twin for power plant and other complex capital-intensive large engineering systems (2022) · cites this paper as Xu et al. (2019)
In the citing paper
“ThermoflowTM with boiler,”
From Digital twin in energy industry: Proposed robust digital twin for power plant and other complex capital-intensive large engineering systems (2022) · cites this paper as Xu et al. (2019)
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sleiti, A. K., Kapat, J. S., & Vesely, L. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.02.305 · Cited by 270
A review on digital twins for power generation and distribution
Heluany, J. B., & Gkioulos, V. (2024) · International Journal of Information Security · doi:10.1007/s10207-023-00784-x · Cited by 122
Development and Integration of a Digital Twin Model for a Real Hydroelectric Power Plant
Ersan, M., & Irmak, E. (2024) · Sensors · doi:10.3390/s24134174 · Cited by 48
“Aspen Plus [35] Thermoflow [36] 3D Java (for Visualization) [37] Ansys [38] COMSOL [39,40] MATLAB [41] Modelica [42] Table 2.”
BackgroundMethodData-efficient digital twin for turbine heat rate of industrial thermal power plant
Ashraf, W. M., Muzammil, S., Nasir, M. W., Muneeb, M., Arafat, S. M., Alshehri, A. S., bin Jumah, A., Debnath, R., Dua, V., & Uddin, G. M. (2026) · Energy · doi:10.1016/j.energy.2026.140238 · Cited by 9
Metadata
- Authors
- Xu, B., Wang, J., Wang, X., Liang, Z., Cui, L., Liu, X., & Ku, A. Y.
- Affiliations
- China Energy National Institute of Clean-and-Low-Carbon Energy, Future Science City, Changping District, Beijing, China
- China Energy Qinhuangdao Power Generation Co. Ltd Qinhuangdao City, Hebei Province, China
- China Energy Fossil Fuel Power Generation Operation Management Center, Fuchengmen, Beijing, China
- Venue
- Clean Energy
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-09
- Volume
- 3
- Issue
- 3
- Pages
- 227-234
- ISSN
- 2515-4230
- 2515-396X
- Cited by
- 73
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A case study of digital-twin-modelling analysis on power-plant-performance optimizations. https://app.cochat.ai/papers/10.1093/ce/zkz025
- The paper
- Xu, B., Wang, J., Wang, X., Liang, Z., Cui, L., Liu, X., & Ku, A. Y. (2019). A case study of digital-twin-modelling analysis on power-plant-performance optimizations. Clean Energy. https://doi.org/10.1093/ce/zkz025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.