Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 63 of the 64 references it cites were found in a registry or an index.

Auditory Feedback Differentially Modulates Behavioral and Neural Markers of Objective and Subjective Performance When Tapping to Your Heartbeat

Open access

Abstract

Interoception, the perception of our body internal signals, plays a key role in maintaining homeostasis and guiding our behavior. Sometimes, we become aware of our body signals and use them in planning and strategic thinking. Here, we show behavioral and neural dissociations between learning to follow one's own heartbeat and metacognitive awareness of one's performance, in a heartbeat-tapping task performed before and after auditory feedback. The electroencephalography amplitude of the heartbeat-evoked potential in interoceptive learners, that is, participants whose accuracy of tapping to their heartbeat improved after auditory feedback, was higher compared with non-learners. However, an increase in gamma phase synchrony (30-45 Hz) after the heartbeat auditory feedback was present only in those participants showing agreement between objective interoceptive performance and metacognitive awareness. Source localization in a group of participants and direct cortical recordings in a single patient identified a network hub for interoceptive learning in the insular cortex. In summary, interoceptive learning may be mediated by the right insular response to the heartbeat, whereas metacognitive awareness of learning may be mediated by widespread cortical synchronization patterns.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cercor/bhv076

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. Experimental design and behavioral findings. Each participant took part in one session consisting of 7 consecutive blocks. In Block 1, participants were instructed to tap in synchrony with an external regular heartbeat (60 Hz, 3 min) aurally delivered through the earphones (A). Block 2 was identical to Block 1 but tapping followed an external irregular heartbeat (A). In the pre-feedback Blocks 3 and 4, which were separated by a short break, participants were asked to tap in synchrony with their own heartbeat (180 taps per block) (B). In the feedback Block 5, participants were asked to tap in synchrony with their own heartbeat while delivered through a stethoscope (180 taps) (C). In the post-feedback Blocks 6 and 7, participants received the same instructions as in Blocks 3 and 4 (D). After each block, participants were asked to rate their performance on a scale from 1 (bad) to 10 (good). After the final block, participants were asked to rate how much their performance accuracy improved after the feedback blocks on a scale from 1 (did not improve) to 10 (improved) (E). Participants (n = 33) were separated into 2 groups: learners (n = 14), whose tapping accuracy significantly improved in the post-feedback blocks compared with the pre-feedback blocks (paired t-test: P < 0.05), and non-learners (n = 19), who did not show a performance improvement after the feedback block. Tapping accuracies are presented separately for each individual, with shorter values indicating more accurate performance. Mean individual tapping accuracies are shown by each dot and its corresponding SEM bars, separately for the pre-feedback (blue) and the post-feedback (red) conditions (see Materials and Methods for more details).
Figure 1. Experimental design and behavioral findings. Each participant took part in one session consisting of 7 consecutive blocks. In Block 1, participants were instructed to tap in synchrony with an external regular heartbeat (60 Hz, 3 min) aurally delivered through the earphones (A). Block 2 was identical to Block 1 but tapping followed an external irregular heartbeat (A). In the pre-feedback Blocks 3 and 4, which were separated by a short break, participants were asked to tap in synchrony with their own heartbeat (180 taps per block) (B). In the feedback Block 5, participants were asked to tap in synchrony with their own heartbeat while delivered through a stethoscope (180 taps) (C). In the post-feedback Blocks 6 and 7, participants received the same instructions as in Blocks 3 and 4 (D). After each block, participants were asked to rate their performance on a scale from 1 (bad) to 10 (good). After the final block, participants were asked to rate how much their performance accuracy improved after the feedback blocks on a scale from 1 (did not improve) to 10 (improved) (E). Participants (n = 33) were separated into 2 groups: learners (n = 14), whose tapping accuracy significantly improved in the post-feedback blocks compared with the pre-feedback blocks (paired t-test: P < 0.05), and non-learners (n = 19), who did not show a performance improvement after the feedback block. Tapping accuracies are presented separately for each individual, with shorter values indicating more accurate performance. Mean individual tapping accuracies are shown by each dot and its corresponding SEM bars, separately for the pre-feedback (blue) and the post-feedback (red) conditions (see Materials and Methods for more details).CC BY-NC · PubMed Central
Figure 2. Heartbeat evoked potentials in interoceptive learners and non-learners. (A–F) Statistically significant temporal clusters of HEP (see Materials and Methods). The central and right frontal ROI showed significant differences between the pre- (blue line) and the post-feedback (red line) conditions for (B and C) learners, but not for (E and F) non-learners. On the contrary, left-frontal ROIs did not show differences between (A) learners and (D) non-learners. Gray-shaded areas indicate significant differences and shadow bars SEM.
Figure 2. Heartbeat evoked potentials in interoceptive learners and non-learners. (A–F) Statistically significant temporal clusters of HEP (see Materials and Methods). The central and right frontal ROI showed significant differences between the pre- (blue line) and the post-feedback (red line) conditions for (B and C) learners, but not for (E and F) non-learners. On the contrary, left-frontal ROIs did not show differences between (A) learners and (D) non-learners. Gray-shaded areas indicate significant differences and shadow bars SEM.CC BY-NC · PubMed Central
Figure 3. Heartbeat evoked potentials in objective and subjective performance. Temporal clustering analysis showed differences between the group of interoceptive learners (n = 14, purple line) and non-learners (n = 19, pink line) for the (A) left-frontal (blue), (B) centro-frontal (green), and (C) right frontal (red) regions when they were split according to the accuracy of their objective performance. Similar group-level analysis based on subjective performance found no significant group differences between learners (n = 15, light green) and non-learners (n = 18, dark green) either for (D) the left-frontal, (E) the centro-frontal, and (F) the right frontal ROI. Gray-shaded areas indicate significant differences between the conditions and shadowed bars around potentials indicate SEM.
Figure 3. Heartbeat evoked potentials in objective and subjective performance. Temporal clustering analysis showed differences between the group of interoceptive learners (n = 14, purple line) and non-learners (n = 19, pink line) for the (A) left-frontal (blue), (B) centro-frontal (green), and (C) right frontal (red) regions when they were split according to the accuracy of their objective performance. Similar group-level analysis based on subjective performance found no significant group differences between learners (n = 15, light green) and non-learners (n = 18, dark green) either for (D) the left-frontal, (E) the centro-frontal, and (F) the right frontal ROI. Gray-shaded areas indicate significant differences between the conditions and shadowed bars around potentials indicate SEM.CC BY-NC · PubMed Central
Figure 4. Sources of heartbeat evoked potentials pre- and post-auditory heartbeat feedback. Activation time courses at ROI visually identified in the cortical maps 200–600 ms after the R-peak. Activity in the right frontal operculum (black dashed circles) showed a significant increase from the pre-feedback condition (A) to the post-feedback condition in learners (B), but not in non-learners (E and F). Activation maps are given only for the ROIs, plotted at the peak of the highest activation time point and the amplitude of the frontal operculum ROI in the pre-feedback and post-feedback conditions for the group of (C) interoceptive learners and (D) non-learners.
Figure 4. Sources of heartbeat evoked potentials pre- and post-auditory heartbeat feedback. Activation time courses at ROI visually identified in the cortical maps 200–600 ms after the R-peak. Activity in the right frontal operculum (black dashed circles) showed a significant increase from the pre-feedback condition (A) to the post-feedback condition in learners (B), but not in non-learners (E and F). Activation maps are given only for the ROIs, plotted at the peak of the highest activation time point and the amplitude of the frontal operculum ROI in the pre-feedback and post-feedback conditions for the group of (C) interoceptive learners and (D) non-learners.CC BY-NC · PubMed Central
Figure 5. Heartbeat evoked potentials in an epileptic patient temporarily implanted with depth intracranial electrodes. (A) LFP analysis revealed a negative HEP signal in the right anterior insula (red) and a nearly symmetric LFP signal (opposite polarity) in the right orbitofrontal cortex (blue). Analysis of the LFP signal from the right motor cortex (cyan—control site) revealed no HEP-like waveforms. (B–D) Cortical location of the electrodes shown in the patient's MRI (Table 1).
Figure 5. Heartbeat evoked potentials in an epileptic patient temporarily implanted with depth intracranial electrodes. (A) LFP analysis revealed a negative HEP signal in the right anterior insula (red) and a nearly symmetric LFP signal (opposite polarity) in the right orbitofrontal cortex (blue). Analysis of the LFP signal from the right motor cortex (cyan—control site) revealed no HEP-like waveforms. (B–D) Cortical location of the electrodes shown in the patient's MRI (Table 1).CC BY-NC · PubMed Central
Figure 6. Gamma phase synchrony modulates metacognitive awareness. All values are expressed in standard deviations (SD) to the baseline. (A) Phase synchrony locked to the ECG R-peak across all electrodes in the metacognitively congruent group and also in the incongruent group (D). The time–frequency chart plots the difference between the pre-feedback and post-feedback conditions. (B) Gamma phase synchrony in the 30- to 45-Hz frequency range between the pre-feedback (blue) and post-feedback (red) conditions. (C) Phase synchrony during pre-feedback (left) and post-feedback (right) conditions in the metacognitively congruent group. Synchrony between electrode pairs in blue lines (pre-feedback) and red lines (post-feedback), only for significant differences compared with a contrast condition (P < 0.01). Time intervals to the R-peak. (D, E, and F) Depicting the same results as A, B, and C, but for the metacognitively incongruent group.
Figure 6. Gamma phase synchrony modulates metacognitive awareness. All values are expressed in standard deviations (SD) to the baseline. (A) Phase synchrony locked to the ECG R-peak across all electrodes in the metacognitively congruent group and also in the incongruent group (D). The time–frequency chart plots the difference between the pre-feedback and post-feedback conditions. (B) Gamma phase synchrony in the 30- to 45-Hz frequency range between the pre-feedback (blue) and post-feedback (red) conditions. (C) Phase synchrony during pre-feedback (left) and post-feedback (right) conditions in the metacognitively congruent group. Synchrony between electrode pairs in blue lines (pre-feedback) and red lines (post-feedback), only for significant differences compared with a contrast condition (P < 0.01). Time intervals to the R-peak. (D, E, and F) Depicting the same results as A, B, and C, but for the metacognitively incongruent group.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 64 references

Cited by

See all 159

Metadata

Authors
Canales-Johnson, A., Silva, C., Huepe, D., Rivera-Rei, Á., Noreika, V., Garcia, M. D. C., Silva, W., Ciraolo, C., Vaucheret, E., Sedeño, L., Couto, B., Kargieman, L., Baglivo, F., Sigman, M., Chennu, S., Ibáñez, A., Rodríguez, E., & Bekinschtein, T. A.
Affiliations
  • Universidad Diego Portales (CL)
  • MRC Cognition and Brain Sciences Unit (GB)
  • Hospital Italiano de Buenos Aires (AR)
  • Favaloro University (AR)
  • Universidad Torcuato Di Tella (AR)
  • University of Cambridge (GB)
  • Australian Research Council (AU)
  • Pontificia Universidad Católica de Chile (CL)
Venue
Cerebral Cortex
Published
2015-04-21
Volume
25
Issue
11
Pages
4490-4503
ISSN
  • 1047-3211 (ISSN-L)
  • 1460-2199
OpenAlex
W2165375691
Cited by
146
References
64
Citations by year
2026: 13 · 2025: 11 · 2024: 9 · 2023: 9 · 2022: 7 · 2021: 21 · 2020: 16 · 2019: 15 · 2018: 10 · 2017: 17 · 2016: 15 · 2015: 3
FWCI
9.02
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Cerebral Cortex (publishedVersion)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • Americanae (AECID Library) (submittedVersion, cc-by-nc-sa)
  • Kent Academic Repository (University of Kent) (submittedVersion)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, cc-by-nc-sa)
Funders
Wellcome Trust (WT093811MA)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neuroscience and Music Perception
  • Health Sciences › Medicine › Psychiatry and Mental health › Psychosomatic Disorders and Their Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
interoception, auditory feedback, metacognitive awareness, heartbeat-evoked potentials, insula
MeSH terms
Acoustic Stimulation, Adult, Analysis of Variance, Awareness, Electrocardiography, Electroencephalography, Epilepsy, Evoked Potentials, Auditory, Female, Heart Rate, Humans, Male, Psychomotor Performance, Time Perception, Cluster Analysis, Young Adult, Feedback, Sensory, Interoception

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Auditory Feedback Differentially Modulates Behavioral and Neural Markers of Objective and Subjective Performance When Tapping to Your Heartbeat. https://app.cochat.ai/papers/10.1093/cercor/bhv076
The paper
Canales-Johnson, A., Silva, C., Huepe, D., Rivera-Rei, Á., Noreika, V., Garcia, M. D. C., Silva, W., Ciraolo, C., Vaucheret, E., Sedeño, L., Couto, B., Kargieman, L., Baglivo, F., Sigman, M., Chennu, S., Ibáñez, A., Rodríguez, E., & Bekinschtein, T. A. (2015). Auditory Feedback Differentially Modulates Behavioral and Neural Markers of Objective and Subjective Performance When Tapping to Your Heartbeat. Cerebral Cortex. https://doi.org/10.1093/cercor/bhv076

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.