Determination of Plasma Lipid Profiles by Automated Gas Chromatography and Computerized Data Analysis
The DOI matches its Crossref record.
Abstract
Plasma or serum [ 0.1-1.0 ml] was digested with phospholipase C and total lipid extracts were prepared and silylated in the presence of tridecanoylglycerol as internal standard. The neutral lipid and free fatty acid profiles were determined by means of an automated GLC system equipped with an unheated on-column inlet, time actuated liquid injector, programmed heating, cooling and equilibration cycles, and an electronic peak area integrator. The separations were accomplished on a 50 cm x 2 mm i.d. steel column packed with 3% OV-1 on100-120 mesh Gas Chrom Q using nitrogen as a carrier gas in the temperature range 175-350 degrees C. The tube number, peak retention time and peak area were recorded on a punched paper tape, which was subsequently read into a computer via a time-share terminal. The composition of the sample was calculated in relation to the internal standard using a modification of a commercially available computer program and the results were expressed as mg or mole % and characteristic molar ratios of lipid classes. In addition to estimates for total cholesterol and triglyceride, the method provides a detailed account of individual or small groups of molecular species of various lipid classes, which is a major advantage over other automated methods of plasma lipid analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lipoprotein abnormalities associated with a familial deficiency of hepatic lipase
BRECKENRIDGE, W., LITTLE, J., ALAUPOVIC, P., WANG, C., KUKSIS, A., KAKIS, G., LINDGREN, F., & GARDINER, G. (1982) · Atherosclerosis · doi:10.1016/0021-9150(82)90136-8 · Cited by 328
Self-citationTriglyceride enrichment of HDL enhances in vivo metabolic clearance of HDL apo A-I in healthy men
Lamarche, B., Uffelman, K. D., Carpentier, A., Cohn, J. S., Steiner, G., Barrett, P. H., & Lewis, G. F. (1999) · Journal of Clinical Investigation · doi:10.1172/jci5286 · Cited by 229
“The phospholipid content of HDL before and after Intralipid was analyzed according to standardized procedures (24, 25).”
MethodFactors underlying the variability of lipid droplet fluorescence in MA‐10 leydig tumor cells
Gocze, P. M., & Freeman, D. A. (1994) · Cytometry · doi:10.1002/cyto.990170207 · Cited by 221
Jellum, E. (1977) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)81792-2 · Cited by 211
Dashti, N., & Wolfbauer, G. (1987) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)38686-7 · Cited by 176
Inhibition of lipoprotein lipase activity by synthetic peptides of apolipoprotein C-III.
McConathy, W., Gesquiere, J., Bass, H., Tartar, A., Fruchart, J. C., & Wang, C. (1992) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)41415-4 · Cited by 173
Human plasma lecithin-cholesterol acyltransferase. An elucidation of the catalytic mechanism.
Jauhiainen, M., & Dolphin, P. J. (1986) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)62718-3 · Cited by 169
Metadata
- Authors
- Kuksis, A., Myher, J. J., Marai, L., & Geher, K.
- Venue
- Journal of Chromatographic Science
- Publisher
- Oxford University Press (OUP)
- Published
- 1975-09-01
- Volume
- 13
- Issue
- 9
- Pages
- 423-430
- ISSN
- 0021-9665 (ISSN-L)
- 1945-239X
- OpenAlex
- W2329380505
- Cited by
- 176
- References
- 0
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.