The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Central Line-Associated Bloodstream Infection in Hospitalized Children with Peripherally Inserted Central Venous Catheters: Extending Risk Analyses Outside the Intensive Care Unit
Open accessAbstract
BACKGROUND: Increasingly, peripherally inserted central venous catheters (PICCs) are placed for prolonged intravenous access. Few data exist regarding risk factors for central line-associated bloodstream infection (CLABSI) complicating PICCs in hospitalized children, especially children hospitalized outside the intensive care unit (ICU). METHODS: We identified all children with a PICC inserted at The Johns Hopkins Hospital (Baltimore, MD) from 1 January 2003 through 31 December 2009 and used Poisson regression models to identify risk factors for PICC-associated CLABSIs. RESULTS: A total of 2592 PICCs were placed in 1819 children. One hundred sixteen CLABSIs occurred over 44,972 catheter-days (incidence rate [IR], 2.58 cases per 1000 catheter-days; 95% confidence interval [CI], 2.07-3.00 cases per 1000 catheter-days). Independent predictors of CLABSI in the entire cohort included PICC dwell time of > 21 days (IR ratio [IRR], 1.53; 95% CI, 1.05-2.26), parenteral nutrition as indication for insertion (IRR, 2.24; 95% CI, 1.31-3.84), prior PICC-associated CLABSI (IRR, 2.48; 95% CI, 1.18-5.25), underlying metabolic condition (IRR, 2.07; 95% CI, 1.14-3.74), and pediatric ICU exposure during hospitalization (IRR, 1.80; 95% CI, 1.18-2.75). Risk factors for CLABSI in children without PICU exposure included younger age, underlying malignancy and metabolic conditions, PICCs inserted in the lower extremity, and a prior PICC-associated CLABSI. CONCLUSIONS: Prolonged catheter dwell time, pediatric ICU exposure, and administration of parenteral nutrition as the indication for PICC insertion are important predictors of PICC-associated CLABSI in hospitalized children. A careful assessment of these risk factors may be important for future success in preventing CLABSIs in hospitalized children with PICCs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
Cited by
Pappas, P. G., Kauffman, C. A., Andes, D. R., Clancy, C. J., Marr, K. A., Ostrosky-Zeichner, L., Reboli, A. C., Schuster, M. G., Vazquez, J. A., Walsh, T. J., et al. (2016) · Clinical Infectious Diseases · doi:10.1093/cid/civ933 · Cited by 4,200
Feudtner, C., Feinstein, J. A., Zhong, W., Hall, M., & Dai, D. (2014) · BMC Pediatrics · doi:10.1186/1471-2431-14-199 · Cited by 1,763
Health care-associated infections – an overview
Haque, M., Sartelli, M., McKimm, J., & Abu Bakar, M. B. (2018) · Infection and Drug Resistance · doi:10.2147/idr.s177247 · Cited by 1,200
Complications of Central Venous Access Devices: A Systematic Review
Ullman, A. J., Marsh, N., Mihala, G., Cooke, M., & Rickard, C. M. (2015) · Pediatrics · doi:10.1542/peds.2015-1507 · Cited by 345
Chopra, V., O'Horo, J. C., Rogers, M. A. M., Maki, D. G., & Safdar, N. (2013) · Infection Control & Hospital Epidemiology · doi:10.1086/671737 · Cited by 339
Metadata
- Authors
- Advani, S., Reich, N. G., Sengupta, A., Gosey, L., & Milstone, A. M.
- Venue
- Clinical Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-04-04
- Volume
- 52
- Issue
- 9
- Pages
- 1108-1115
- ISSN
- 1058-4838 (ISSN-L)
- 1537-6591
- OpenAlex
- W2102887021
- Cited by
- 158
- References
- 1
- FWCI
- 21.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Central Line-Associated Bloodstream Infection in Hospitalized Children with Peripherally Inserted Central Venous Catheters: Extending Risk Analyses Outside the Intensive Care Unit. https://app.cochat.ai/papers/10.1093/cid/cir145
- The paper
- Advani, S., Reich, N. G., Sengupta, A., Gosey, L., & Milstone, A. M. (2011). Central Line-Associated Bloodstream Infection in Hospitalized Children with Peripherally Inserted Central Venous Catheters: Extending Risk Analyses Outside the Intensive Care Unit. Clinical Infectious Diseases. https://doi.org/10.1093/cid/cir145
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.