The DOI matches its Crossref record.
An Evaluation of Environmental Decontamination With Hydrogen Peroxide Vapor for Reducing the Risk of Patient Acquisition of Multidrug-Resistant Organisms
Abstract
BACKGROUND: Admission to a room previously occupied by a patient with certain multidrug-resistant organisms (MDROs) increases the risk of acquisition. Traditional cleaning strategies do not remove all environmental MDROs. We evaluated the environmental and clinical impact of hydrogen peroxide vapor (HPV) room disinfection. METHODS: We performed a 30-month prospective cohort intervention study on 6 high-risk units in a 994-bed tertiary care hospital. Following a 12-month preintervention phase, HPV was implemented on 3 units to decontaminate the rooms of patients known to be infected or colonized with epidemiologically important MDROs, following their discharge. Monthly environmental samples for MDROs were collected on all study units for 3 preintervention and 6 intervention months. The risk of MDRO acquisition in patients admitted to rooms decontaminated using HPV was compared with rooms disinfected using standard methods. RESULTS: The prior room occupant was known to be infected or colonized with an MDRO in 22% of 6350 admissions. Patients admitted to rooms decontaminated using HPV were 64% less likely to acquire any MDRO (incidence rate ratio [IRR], 0.36; 95% confidence interval [CI], .19-.70; P < .001) and 80% less likely to acquire VRE (IRR, 0.20; 95% CI, .08-.52; P < .001) after adjusting for other factors. The risk of acquiring Clostridium difficile, methicillin-resistant Staphylococcus aureus, and multidrug-resistant gram-negative rods individually was reduced, but not significantly. The proportion of rooms environmentally contaminated with MDROs was reduced significantly on the HPV units (relative risk, 0.65, P = .03), but not on non-HPV units. CONCLUSIONS: HPV decontamination reduced environmental contamination and the risk of acquiring MDROs compared with standard cleaning protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Dancer, S. J. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-14 · Cited by 679
Otter, J. A., Yezli, S., Salkeld, J. A. G., & French, G. L. (2013) · American Journal of Infection Control · doi:10.1016/j.ajic.2012.12.004 · Cited by 594
Self-citationThe role of the surface environment in healthcare-associated infections
Weber, D. J., Anderson, D., & Rutala, W. A. (2013) · Current Opinion in Infectious Diseases · doi:10.1097/qco.0b013e3283630f04 · Cited by 567
Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals
Boyce, J. M. (2016) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-016-0111-x · Cited by 442
Metadata
- Authors
- Passaretti, C. L., Otter, J. A., Reich, N. G., Myers, J., Shepard, J., Ross, T., Carroll, K. C., Lipsett, P., & Perl, T. M.
- Venue
- Clinical Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-10-05
- Volume
- 56
- Issue
- 1
- Pages
- 27-35
- ISSN
- 1058-4838 (ISSN-L)
- 1537-6591
- OpenAlex
- W2154611004
- Cited by
- 220
- References
- 0
- FWCI
- 17.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Evaluation of Environmental Decontamination With Hydrogen Peroxide Vapor for Reducing the Risk of Patient Acquisition of Multidrug-Resistant Organisms. https://app.cochat.ai/papers/10.1093/cid/cis839
- The paper
- Passaretti, C. L., Otter, J. A., Reich, N. G., Myers, J., Shepard, J., Ross, T., Carroll, K. C., Lipsett, P., & Perl, T. M. (2013). An Evaluation of Environmental Decontamination With Hydrogen Peroxide Vapor for Reducing the Risk of Patient Acquisition of Multidrug-Resistant Organisms. Clinical Infectious Diseases. https://doi.org/10.1093/cid/cis839
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.