CoChat

Performance of Treponemal Tests for the Diagnosis of Syphilis

Open access
Park, Ina U, Fakile, Yetunde F, Chow, Joan M, Gustafson, Kathleen J, Jost, Heather, Schapiro, Jeffrey M, Novak-Weekley, Susan, Tran, Anthony, Nomura, Jim H, Chen, Victor, Beheshti, Manie, Tsai, Townson, Hoover, Karen, Bolan, Gail · 2019 · Clinical Infectious Diseases
Cited by 122

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Treponemal immunoassays are increasingly used for syphilis screening with the reverse sequence algorithm. There are few data describing performance of treponemal immunoassays compared to traditional treponemal tests in patients with and without syphilis. METHODS: We calculated sensitivity and specificity of 7 treponemal assays: (1) ADVIA Centaur (chemiluminescence immunoassay [CIA]); (2) Bioplex 2200 (microbead immunoassay); (3) fluorescent treponemal antibody absorption test (FTA-ABS); (4) INNO-LIA (line immunoassay); (5) LIAISON CIA; (6) Treponema pallidum particle agglutination assay (TPPA); and (7) Trep-Sure (enzyme immunoassay [EIA]), using a reference standard combining clinical diagnosis and serology results. Sera were collected between May 2012-January 2013. Cases were characterized as: (1) current clinical diagnosis of syphilis: primary, secondary, early latent, late latent; (2) prior treated syphilis only; (3) no evidence of current syphilis, no prior history of syphilis, and at least 4 of 7 treponemal tests negative. RESULTS: Among 959 participants, 262 had current syphilis, 294 had prior syphilis, and 403 did not have syphilis. FTA-ABS was less sensitive for primary syphilis (78.2%) than the immunoassays or TPPA (94.5%-96.4%) (all P ≤ .01). All immunoassays were 100% sensitive for secondary syphilis, 95.2%-100% sensitive for early latent disease, and 86.8%-98.5% sensitive in late latent disease. TPPA had 100% specificity. CONCLUSIONS: Treponemal immunoassays demonstrated excellent sensitivity for secondary, early latent, and seropositive primary syphilis. Sensitivity of FTA-ABS in primary syphilis was poor. Given its high specificity and superior sensitivity, TPPA is preferred to adjudicate discordant results with the reverse sequence algorithm over the FTA-ABS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cid/ciy558

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 122

Metadata

Authors
Park, I. U., Fakile, Y. F., Chow, J. M., Gustafson, K. J., Jost, H., Schapiro, J. M., Novak-Weekley, S., Tran, A., Nomura, J. H., Chen, V., Beheshti, M., Tsai, T., Hoover, K., & Bolan, G.
Venue
Clinical Infectious Diseases
Published
2018-07-09
Volume
68
Issue
6
Pages
913-918
ISSN
  • 1058-4838 (ISSN-L)
  • 1537-6591
OpenAlex
W2876703464
Cited by
122
References
2
FWCI
6.38
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of Treponemal Tests for the Diagnosis of Syphilis. https://app.cochat.ai/papers/10.1093/cid/ciy558
The paper
Park, I. U., Fakile, Y. F., Chow, J. M., Gustafson, K. J., Jost, H., Schapiro, J. M., Novak-Weekley, S., Tran, A., Nomura, J. H., Chen, V., Beheshti, M., Tsai, T., Hoover, K., & Bolan, G. (2019). Performance of Treponemal Tests for the Diagnosis of Syphilis. Clinical Infectious Diseases. https://doi.org/10.1093/cid/ciy558

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.