Cited by 2HIV Research and TreatmentHIV/AIDS Research and InterventionsClinical Laboratory Practices and Quality Control

False-negative Results of Human Immunodeficiency Virus (HIV) Rapid Testing in HIV Controllers

Open access
Hage-Sleiman, Mehdi, Tremeaux, Pauline, Fillion, Marine, Boufassa, Faroudy, Melard, Adeline, Gardiennet, Elise, Mariaggi, Alice-Andrée, Plantier, Jean-Christophe +172 more·2020·Clinical Infectious Diseases

Abstract

Serological assays were performed on 85 human immunodeficiency virus-controller samples . 6% presented a negative rapid screening test 7% presented an indeterminate Western blot. The enzyme immunoassay ratio decreased in controllers who had continual negative ultrasensitive HIV RNA results since inclusion.

Integrity signals

Registry

Crossref · 10.1093/cid/ciz734

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • False test results occur in POCT due to intentional or unintentional misuse of the test, equipment failure or poor testing and result management processes.

    “Although POCT are designed to be simple and robust, false test results occur [67], due to intentional or unintentional misuse of the test, equipment failure or poor testing and result management processes.”

    From Point-of-care testing: state-of-the art and perspectives (2025) · cites this paper as [67]

Cited by

Sorted by citations

Authors
Hage-Sleiman, M., Tremeaux, P., Fillion, M., Boufassa, F., Melard, A., Gardiennet, E., Mariaggi, A.-A., Plantier, J.-C., Rouzioux, C., Lambotte, O., Avettand-Fenoel, V., for the CODEX ANRS Cohort Study Group, Faller, J.-P., Roblot, P., Plainchamp, M. D., Aumaître, H., Malet, M., Rouger, C., Rémy, G., Isabelle, M. K., Delassus, J.-L., Devidas, A., Froguel, E., Tassi, S., Genet, P., Gerbe, J., Patey, O., Laurent, R., Drobacheff, M.-C., Proust, A., Gil, H., Gérard, L., Oksenhendler, E., Lucht, F., Ronat, V., Dupon, M., Dutronc, H., Le Puil, S., Schmit, J.-L., Decaux, N., Molina, J.-M., Lascoux, C., Parlier, S., Jean-Pierre, B. R. U., Clavere, G., Lambotte, O., Delfraissy, J.-F., Goujard, C., Bourdic, K., Bergmann, J.-F., Parrinello, M., Pichancourt, G., Welker, Y., Lafeuillade, A., Gisèle, P., Rapp, C., Lerondel, M., de Truchis, P., Berthe, H., Jeantils, V., Mchangama, F., Vittecoq, D., Bolliot, C., Consigny, P. H., Touam, F., Pialoux, G., le Nagat, S., Bouchaud, O., Honoré, P., Boué, F., Raho-Moussa, M., Weiss, L., Collias, L., Salmon-Céron, D., Pietri, M.-P., Zucman, D., Blétry, O., Bornarel, D., Mortier, E., Feng, Z., Lelièvre, J.-D., Katlama, C., Dudoit, Y., Simon, A., Lupin, C., Girard, P.-M., Pauchard, M., Abel, S., Cabié, A., Fialaire, P., Chennebault, J.-M., Rehaiem, M. S., Martin, L. D. S., Perfezou, P., Duthe, M. J.-C., Morlat, P., Caldato, S., Neau, D., LE Puil, S., Weinbreck, P., Genet, C., Makhloufi, D., GARNIER, F., Poizot-Martin, I., Fauche, O., Ivanova, A., Yeni, P., Matheron, S., Cyndi, G., Raffi, F., Hervé Hüe, M., Perré, P., Roger, P. M., Joulie, A., Rosenthal, É., Michelet, C., Souala, F., Ratajczak, M., Partisani, M., Fischer, P., Bernard, L., Nau, P., Marchou, B., Balsarin, F., Verdon, R., Feret, P., Jacomet, C., Piroth, L., Gohier, S., Leclercq, P., Meybeck, A., Biekre, R., May, T., Caron, F., Debab, Y., Theron, M. D., Miailhes, P., Ogoudjobi, M. S., Mercié, P., Gatfosse, M., Martinot, M., Pachart, A., Poubeau, P., Uludag, A., Arsac, P., Bouaraba, L., Szmania, I. D. L., Richier, M. L., Daneluzzi, V., Rouveix, E., Beck-Wirth, G., Romand, P., Blum, L., Deschaud, M., Michau, C., Bernard, C., Salaun, F., Muller, P., Poinsignon, Y., Lepretre, A., Deschaud, M., Lambert, T., Hocqueloux, L., de Dieulevault, B., Philibert, P., Sow, M. P., Sotto, A., Viard, J.-P., Cros, A., De Lavaissiere, M., Duthe, M. J. C., Gaud, C., Niault, M. A., Mouton-Rioux, V., Talarmin, J., Duthé, M. J. C., Mathilde, D., Natur, M. S., Hitoto, H., & Ibrahim, M. A. M.
Affiliations
  • Hôpital Necker-Enfants Malades (FR)
  • Université Paris Descartes, Sorbonne Paris Cité, Faculté de Médecine, Paris, France
  • Centre National de la Recherche Scientifique (FR)
  • Université Paris-Sud (FR)
  • Hôpital Charles-Nicolle (FR)
  • Sorbonne Paris Cité (FR)
  • AP-HP, Laboratoire de Microbiologie Clinique, Hôpital Necker-Enfants Malades, Paris, France
Venue
Clinical Infectious Diseases
Published
2019-09-21
Volume
70
Issue
8
Pages
1754-1757
ISSN
  • 1058-4838 (ISSN-L)
  • 1537-6591
OpenAlex
W2973905488
Cited by
2
References
0
Citations by year
2024: 1 · 2021: 1
FWCI
0.14
Type
journal article
Language
en
Open access
Locations
  • Clinical Infectious Diseases (publishedVersion)
  • PubMed (publishedVersion)
  • HAL (submittedVersion)
Funders
ANRS
Topics
  • Life Sciences › Immunology and Microbiology › Virology › HIV Research and Treatment
  • Health Sciences › Medicine › Infectious Diseases › HIV/AIDS Research and Interventions
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
HIV controllers, rapid HIV testing, false-negative results, HIV serology, HIV screening
MeSH terms
Negative Results, Enzyme-Linked Immunosorbent Assay, HIV, Humans, Immunoenzyme Techniques, Blotting, Western, HIV Antibodies, HIV-2, HIV Infections

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review