The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Direct Spectrophotometric Determination of Albumin in Human Serum
Abstract
In a convenient and direct method for determination of albumin in human serum, based on the decrease in absorbance of a neutral buffered solution of bromcresol green when albumin combines with the indicator, serum is diluted with a solution of bromcresol green of sufficient concentration to allow essentially linear change of absorbance with albumin concentration. Measurements are made at 615 mµ, where the absorbance of hemoglobin or bilirubin does not interfere. Extremely lipemic, turbid serums may be accurately analyzed. This method has been applied to a number of abnormal serums and compared with measurements of the albumin fraction of serum which is soluble in 2% (w/v) TCA in ethanol. Satisfactory agreement was obtained. Tests indicated that bromcresol green was not bound by serum globulins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Chemistry. Principles and Technics.
(1964) · Annals of Internal Medicine · doi:10.7326/0003-4819-61-3-607_1 · Cited by 893
Quantitative Organic Microanalysis
Pregl, F. (1968) · Harvard University Press eBooks · doi:10.4159/harvard.9780674366701.c6 · Cited by 325
Körner, A., & Debro, J. R. (1956) · Nature · doi:10.1038/1781067a0 · Cited by 141
Rutstein, D. D., Ingenito, E. F., Reynolds, W. E., & Burke, J. M. (1954) · Journal of Clinical Investigation · doi:10.1172/jci102887 · Cited by 114
Cited by
Albumin standards and the measurement of serum albumin with bromcresol green
Doumas, B. T., Ard Watson, W., & Biggs, H. G. (1971) · Clinica Chimica Acta · doi:10.1016/0009-8981(71)90365-2 · Cited by 3,062
Albumin standards and the measurement of serum albumin with bromcresol green
Doumas, B. T., Ard Watson, W., & Biggs, H. G. (1997) · Clinica Chimica Acta · doi:10.1016/s0009-8981(96)06447-9 · Cited by 2,767
Södergard, R., Bäckström, T., Shanbhag, V., & Carstensen, H. (1982) · Journal of Steroid Biochemistry · doi:10.1016/0022-4731(82)90038-3 · Cited by 1,080
Marital quality, marital disruption, and immune function.
Kiecolt-Glaser, J. K., Fisher, L. D., Ogrocki, P., Stout, J. C., Speicher, C. E., & Glaser, R. (1987) · Psychosomatic Medicine · doi:10.1097/00006842-198701000-00002 · Cited by 661
Chronic stress and immunity in family caregivers of Alzheimerʼs disease victims.
Kiecolt-Glaser, J. K., Glaser, R., Shuttleworth, E. C., Dyer, C. S., Ogrocki, P., & Speicher, C. E. (1987) · Psychosomatic Medicine · doi:10.1097/00006842-198709000-00008 · Cited by 485
Metadata
- Authors
- Rodkey, F. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1965-04-01
- Volume
- 11
- Issue
- 4
- Pages
- 478-487
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1922526566
- Cited by
- 415
- References
- 4
- FWCI
- 0.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.