Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 171

The DOI matches its Crossref record.

An Improved Automated Determination of Serum Total Cholesterol with a Single Color Reagent

Block, Walter D, Jarrett, K John, Levine, Jacob B · 1966 · Clinical Chemistry

Abstract

An anhydrous color reagent containing ferric chloride is pumped through Tygon tubing to a glass coil in a 95° heating bath. Manually prepared serum extracts (1:20 isopropanol dilution) are presented to the stream of preheated color reagent, and the two are passed through three mixing coils, connected in series. The absorbance of the resultant color is determined at 550 mµ in a 15 mm. tubular flow-cell. The improved N-automated procedure gave values of greater precision (5.6%) for total cholesterol determined in replicate samples from sera pools than the N-automated procedure which lacked precision (27.7%). The values found in 60 individual serums are within 6.0% of total cholesterol values determined by the Abell et al. method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/12.10.681

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 171

Metadata

Authors
Block, W. D., Jarrett, K. J., & Levine, J. B.
Venue
Clinical Chemistry
Published
1966-10-01
Volume
12
Issue
10
Pages
681-689
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1962620101
Cited by
171
References
0
FWCI
9.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Improved Automated Determination of Serum Total Cholesterol with a Single Color Reagent. https://app.cochat.ai/papers/10.1093/clinchem/12.10.681
The paper
Block, W. D., Jarrett, K. J., & Levine, J. B. (1966). An Improved Automated Determination of Serum Total Cholesterol with a Single Color Reagent. Clinical Chemistry. https://doi.org/10.1093/clinchem/12.10.681

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.