New Colorimetric Reaction for End-Point, Continuous-Flow, and Kinetic Measurement of Urea

Jung, David, Biggs, Homer, Erikson, John, Ledyard, Peggy U · 1975 · Clinical Chemistry

Abstract

A reaction of urea, o-phthalaldehyde and N-(1-naphthyl)ethylenediamine is described for measurement of urea by manual, continuous-flow, and kinetic methods. The continuous-flow system requires 25 µl of sample; 40 samples can be analyzed per hour. The kinetic method requires no enzymes, has no lag phase, and has good sensitivity. A major advantage of the reaction is that it occurs at a temperature of 37 °C or lower. The results obtained by all three methods agree well with those for a continuous-flow procedure in which diacetyl is a reagent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/21.8.1136

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 165

Metadata

Authors
Jung, D., Biggs, H., Erikson, J., & Ledyard, P. U.
Venue
Clinical Chemistry
Published
1975-07-01
Volume
21
Issue
8
Pages
1136-1140
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1885031028
Cited by
165
References
0
FWCI
1.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New Colorimetric Reaction for End-Point, Continuous-Flow, and Kinetic Measurement of Urea. https://app.cochat.ai/papers/10.1093/clinchem/21.8.1136
The paper
Jung, D., Biggs, H., Erikson, J., & Ledyard, P. U. (1975). New Colorimetric Reaction for End-Point, Continuous-Flow, and Kinetic Measurement of Urea. Clinical Chemistry. https://doi.org/10.1093/clinchem/21.8.1136

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.