The DOI matches its Crossref record.
An Analytical System for Rapid Separation of Tissue Nucleotides at Low Pressures on Conventional Anion Exchangers
Abstract
An analytical anion-exchange procedure has been developed for the rapid separation of acid-soluble nucleotides (the so-called "free" or tissue nucleotides). It permits assay at low pressures (275-415 kPa; 40-60 psi) in less than 1 h on 10-cm columns of Aminex resins (conventional styrene-type anion exchangers) with alkaline citrate solutions as the eluent. Separation variables have been investigated, to determine optimum conditions for the routine analysis of samples containing tissue nucleotides. Also described here is a simple solvent-extraction procedure for removing HClO4 or CCl3CO2H quantitatively from cell extracts that contain acid-soluble nucleotides: they are removed from aqueous acid solutions with a water-insoluble amine dissolved in a water-immiscible solvent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schraufstatter, I. U., Hinshaw, D. B., Hyslop, P. A., Spragg, R. G., & Cochrane, C. G. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112436 · Cited by 512
Partida-Sanchez, S., Gasser, A., Fliegert, R., Siebrands, C. C., Dammermann, W., Shi, G., Mousseau, B. J., Sumoza-Toledo, A., Bhagat, H., Walseth, T. F., et al. (2007) · The Journal of Immunology · doi:10.4049/jimmunol.179.11.7827 · Cited by 144
Metadata
- Authors
- Khym, J. X.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1975-08-01
- Volume
- 21
- Issue
- 9
- Pages
- 1245-1252
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2096725836
- Cited by
- 530
- References
- 0
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Analytical System for Rapid Separation of Tissue Nucleotides at Low Pressures on Conventional Anion Exchangers. https://app.cochat.ai/papers/10.1093/clinchem/21.9.1245
- The paper
- Khym, J. X. (1975). An Analytical System for Rapid Separation of Tissue Nucleotides at Low Pressures on Conventional Anion Exchangers. Clinical Chemistry. https://doi.org/10.1093/clinchem/21.9.1245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.